Pb Lead-Acid Battery Program
Pb Lead-Acid Battery Program
This program is only suitable for charging Pb
(lead-acid) batteries with nominal voltage
ranging from 2 to 20V. Pb (lead-acid) batteries
are significantly different from NiMH/NiCd
batteries. Pb batteries can only deliver a low
current in relation to their capacity. The same
restriction applies to the charging process.
Consequently, the optimum charge current can
only be 1/10th of the capacity. A Pb battery
cannot be used for fast charging. Please follow
the instructions provided by the battery
manufacturer.
The e660 offers the following Pb charge modes:
Charge and Discharge.
Pb (Lead-Acid):
BATT/PROGRAM
Pb BATT
Pb Charge Mode:
After selecting the correct battery type, use the INC or DEC button to
change it to the “CHARGE“ mode.
Press the START button and the amp rate value will begin flashing. Use
the INC or DEC buttons to adjust the value to the desired charge rate.
The amp rate should be set to 1/10th of capacity. For example, if you are
charging a 20Ah battery the charge rate should be set to 2A. Follow the
instructions provided on your battery when setting the amp rate.
Press the START button again and the nominal
battery pack voltage will begin flashing. Use the
INC or DEC button to set the voltage and the
number of cells.
Press and hold the START button for 3 seconds
to start charging.
Pb Charge
1.5A 12.0V(6
S
)
Once charging has commenced, the charger will
display the following real-time information:
battery type, charging current, battery voltage,
charging time and charged capacity.
When charging is complete, the screen will read “FINISHED” and the
charger will emit a ringing sound.
Pb Discharge Mode:
P-6 1.5A 13.56V
CHG 002:22 00106
After selecting the correct battery type, use the INC or DEC buttons to
change it to the “DISCHARGE“ mode.
Press the START button and the amp rate value will begin flashing. Use
the INC or DEC buttons to adjust the value to the desired discharge
rate. Follow the instructions provided with your battery when setting the
amp rate.
Pb Discharge
1.5A 12.0V(6
S
)
P-6
1.0A
13.56V
DCH
005:10
00964
Press the START button again and the nominal
battery pack voltage will begin flashing. Use the
INC or DEC buttons to set the voltage and the
number of cells.
Press and hold the START button and
discharging will begin.
Once discharging has commenced, the charger
will display the following real-time information:
battery type, discharging current, battery
voltage, discharging time and discharged
capacity.
When discharging is complete, the screen will
read “FINISHED” and the charger will emit a
ringing sound.
Additional Pb Process Information:
During the Pb battery charging/discharging process the e660 can
display a variety of information. Using the INC or DEC buttons you can
also view the following information:
Capacity Cut-Off
ON 5000mAh
In Power Voltage
12.56V
Capacity cut-
off setting
Temperature
cut-off
Input
voltage
External*/ internal
temperature
Ext. Temp ----
Int. Temp 37
C
Temp Cut-off
50
C
Safety Time
ON 200min
Safety timer