22
23
6X80 Plus
6X80 Plus
CHARGE/DISCHARGE & DISCHARGE/CHARGE CYCLE
OF NIMH/NICD BATTERY
- +
- +
Battery
type
Elapsed
time
Battery
voltage
Discharged
or charged
capacity
Discharge
or charge
current
> 3 seconds
NiMH CYCLE
CHG
>
DCHG 1
NiMH 1.0A 7.42V
C>D 022:45 00890
You can set up sequence on the left and the
number of cycles on the right. Range of the
cycle number is 1-5.
Press Mode/Stop key to stop program, you
can rotate the Start/Enter dial to alter the
current.
Mode
Stop
SELECT
SELECT
NIMH/NICD BATTERY PROGRAM
Discharge
current
Battery
type
Battery
voltage
Elapsed
time
Discharged
capacity
NiMH 0.1A 7.42V
DSC 022:45 00890
The screen indicates the discharging state.
You can rotate the Start/Enter dial to alter
discharge current and repress the dial to
store the value. Press Mode/Stop button to
stop discharging.
The audible sound indicates the end of
process.
Press
Dial
PB( LEAD-SULPHURIC ACID) BATTERY PROGRAM
This is programmed for charging Pb (lead-sulphuric acid) battery with
nominal voltage from 2 to 20V. Pb batteries are totally different from
NiMH or NiCd batteries. They can only deliver relatively lower current
comparing to their capacity, and similar restrictions definitely apply to
charge. So the optimal charge current will be 1/10 of the capacity. Pb
batteries must not be charged rapidly. Always follow the instruction
supplied by the battery manufacturer.
CHARGING OF PB BATTERY
Battery
type
-
Elapsed
time
+
Charge
current
Battery
voltage
- +
Charged
capacity
> 3 seconds
Set up the charge current on the left and the
nominal voltage of the battery on the right.
The charge current ranges from 0.1 to 10.0A
and the voltage should be matched with the
battery being charged. Start the charge
process by pressing and holding the dial for
3 seconds.
The screen displays the state of charging
process. To stop charging forcibly, press
Mode/Stop button once.
The audible sound indicates end of process.
DISCHARGING OF PB BATTERY
- +
- +
Set discharge current on the left and final
voltage on the right. The discharge current
ranges from 0.1 to 5.0A.
To start the process, press and hold the
Start/Enter dial for 3 seconds.
SELECT
SELECT
Mode
Stop
SELECT
SELECT
> 3 seconds
Mode
Stop
Press
Dial
Press
Dial