6. Maintenance
Maintenance must be considered a set of procedures with the purpose to keep the
equipment best operating conditions, therefore increasing the equipment life and safety.
* Cleaning – Check item 3.3 Cleaning.
* Wiring – Check all wires regarding deteriorate conditions as well as all electric contacts
(terminals) regarding tightening and corrosion.
* Contacts – ON/OFF switch, emergency button, reset button, electronic circuits etc,
check the equipment in order to assure that all components are correctly working and the
equipment operation is normal.
* Installation – Make sure the installation followed item 2.1 instructions.
1 - Each month check:
- Check the electrical installation;
- Measure the voltage at the socket;
- Measure the working current and match it with the nominal current;
- Check the tightening of all electric terminals to avoid bad contacts ;
- Check electric motor shaft clearance;
- Check the wiring for overeating, insulation failures and mechanical damages.
2 - Each three month checks:
- Check electrical components such as ON/OFF switch, emergency button, reset button,
electronic electric circuits, overeating, insulation failings, or mechanical damages.
- Check bearings clearances.
- Check retainers, O’rings, V’rings and other seals.