213217AAA
SJ85 AJ
54
Section 4 – Pre-operation
Function Tests
4.3-13 Testing footswitch and all boom
and platform functions
1.
Ensure emergency stop button is pulled out.
2.
Ensure engine start/on/off switch is in
on position.
3.
Do not start engine.
4.
Select generator on/off switch to off position (if
equipped).
5.
Depress and hold footswitch and attempt to start
engine by selecting start position from engine
start/on/off switch..
▪
Result:
Engine should not start.
6.
Without depressing footswitch, try to start
engine.
▪
Result:
Engine should start.
7.
With engine running and without depressing
footswitch, test each boom and platform
function.
▪
Result:
MEWP functions should not operate.
NOTE
A 7-second anti-tiedown feature deactivates
footswitch when operator depresses it for 7
seconds without activating any function.
8.
With engine running, depress and hold
footswitch and test all boom and platform
functions.
▪
Result:
All MEWP functions should operate.
4.3-14 Testing boom lowering cutout
switch
1.
With engine running, depress and hold
footswitch and raise main boom 0.6 m
(2 ft).
2.
Fully lower main boom and continue to
command lowering for 5 seconds.
▪
Result:
Main boom should fully lower, riser
should not raise, and there should be an
audible sound when the pump disengages.
4.3-15 Testing platform capacity zone
indicator lights
NOTE
To perform this function test, ensure there is
sufficient space to fully raise and extend boom.
NOTE
Ensure boom is in stowed position to begin this
function test.
1.
Push in emergency stop button.
2.
Pull out emergency stop button.
▪
Result:
Capacity zone border light should
illuminate for 1 second and then turn off. High
capacity zone indicator light should illuminate.
3.
Start engine.
4.
Depress and hold footswitch and extend
boom until high capacity zone indicator light
turns off.
▪
Result:
Low capacity zone indicator light
should illuminate.
TM
1
2
+
+
Reset button
High capacity zone indicator light
Low capacity zone
indicator light
Capacity zone
border light
Emergency stop
Emergency power switch
Содержание 213217AAA
Страница 1: ...OPERATING MANUAL SJ85 AJ ARTICULATING BOOMS 213217AAA December 2018 ANSI CSA...
Страница 4: ...213217AAA SJ85 AJ 4 Notes...
Страница 14: ...213217AAA SJ85 AJ 14 Notes...
Страница 20: ...213217AAA SJ85 AJ 20 Notes...
Страница 38: ...213217AAA SJ85 AJ 38 Notes...
Страница 75: ...SJ85 AJ 213217AAA 75 Section 7 Technical Diagrams Specifications...
Страница 110: ...213217AAA SJ85 AJ 110 Notes...
Страница 111: ...Cancer and Reproductive Harm https www p65warnings ca gov WARNING...
Страница 112: ...www skyjack com...