background image

SkyAzúl,

 

Equipment

 

Solutions

                                     

www.skyazul.com

                                        

301

371

6126

  

EKS

 

83

 

Combined

 

Console

 

and

 

Central

 

Unit

 

 

Components

 

 

1.

 

Mounting screws - Instrument panel

 

2.

 

“ON" light

 

3.

 

Supply voltage indicator light

 

4.

 

Information switch "a" to "k"

 

a.

 

Capacity utilization in %

 

b.

 

Hook height in m

 

c.

 

Main boom length in m

 

d.

 

Main boom angle in degrees

 

e.

 

No function

 

f.

 

Piston surface pressure in 
derricking cylinder In bar

 

g.

 

Piston ring surface pressure in 
derricking cylinder in bar

 

h.

 

(h-k) No function

 

5.

 

Warning light – shutdown

 

6.

 

Release button

 

7.

 

Switch for setting operating mode (SLI code)

 

8.

 

Switch for setting  reeving mode

 

9.

 

SLI brief information display

 

10.

 

Display – information

 

11.

 

Display – radius

 

12.

 

Display - shutdown value

 

13.

 

Display – load

 

14.

 

Status display (operating modes, fault 
messages)

 

15.

 

Fuse F2 (SU 2) for data bus (1.25 

rnA)

 

16.

 

Plug X4 for 24 V power supply

 

17.

 

Fuse F1 (SU 1) (3.15A)

 

18.

 

Output X3 to crane electrics (shutdown 
signals)

 

19.

 

Data bus connection supply Xl for data 
transmitter

 

20.

 

Additional outputs X5

 

21.

 

Digital inputs X2

 

 

 

 

          6

Содержание Krupp EKS 83

Страница 1: ...Krupp EKS 83 Service Manual...

Страница 2: ......

Страница 3: ...y information which is protected by copyright and all rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of...

Страница 4: ......

Страница 5: ...tiometer 8 LMI Transmitter for Pressure Transducers 8 Selection of lifting capacity chart 9 Selection of lifting capacity tables 9 Calculation of the radius 9 Calculation of the reference value 9 Calc...

Страница 6: ...301 371 6126 Information display shows letter c 16 Information display shows letter d 17 Information display shows letter e 19 Information display shows letter f 20 Information display shows letter g...

Страница 7: ...SkyAz l Equipment Solutions www skyazul com 301 371 6126 EKS Load Moment Indicator The combined Console and Central Unit 3...

Страница 8: ...ngle potentiometer and data transmitter for angle and length 5 Pressure sensor on derricking cylinder 6 Display unit on right hand side of turntable 7 Data transmitter for pressure sensor on right han...

Страница 9: ...own is for a GMK407 The position of components in other models may vary and some items might not be fitted 1 Plug in module lOA fuses FI F1 8 2 Plug in module 9 5A with LMI shutdown circuit relay K1 3...

Страница 10: ...surface pressure in derricking cylinder in bar h h k No function 5 Warning light shutdown 6 Release button 7 Switch for setting operating mode SLI code 8 Switch for setting reeving mode 9 9 SLI brief...

Страница 11: ...ith potentiometer for length telescope sections III and IV 2 Cable drum with potentiometer for length telescope sections I and II 3 Boom unit with angle measurement and data transmitter for angle and...

Страница 12: ...rum Potentiometer 1 Using a screwdriver to set the Length Potentiometer to the anti clockwise position with the Boom fully retracted LMI Transmitter for Pressure Transducers 2 Data Transmitter Annular...

Страница 13: ...he inherent moment of the boom the actual load is calculated taking into account the reeving configuration set on the central unit Warning and shutdown in case of overload Reference value and calculat...

Страница 14: ...ssed current via the common dual line data bus to the central unit Transmitter Boards All transmitter Boards fitted on a machine are the same part number The system each board is monitoring is identif...

Страница 15: ...Cut Ofr and Status display will show a code for most transmitter failures it is prefixed with d Note On a number of models a prefix of g will represent certain transmitters i e machines with 4 telesc...

Страница 16: ...is dialed into the 2x Reeving Switches Fault Diagnosis Flow Charts No Buzzer or Displays SU inoperative No buzzer signal No displays dark Power supply switched off Fuse F1 8 plug in module 10A blown F...

Страница 17: ...Overload Call up SLI fault code Select displayed letter using information switch SLI displays letters a k and numbers 1 8 Leave overload range Press SLI release button See corrective action given on...

Страница 18: ...Non authorized reeving mode selected TEXT a 8 Selected operating mode code not possible Central unit faulty Call SkyAzul 301 228 6086 Select correct operating mode Press LMI release button S1 YES YES...

Страница 19: ...ct country set for Rating calibrated into CPU 75 85 etc Central unit faulty Call SkyAzul 301 228 6086 a Customer Options Not registering with CPU OR b Telescope section No 1 not locked check lock syst...

Страница 20: ...section 2 YES NO NO NO TEXT c 3 Telescope section 3 not locked Lock inspect locking mechanism of tele section 3 YES NO TEXT c 4 Telescope section 4 not locked Lock inspect locking mechanism of tele s...

Страница 21: ...s pull central unit out of Instrument panel replace fuse F2 1 25 A Fuse blown again Short circuit in the system Call SkyAzul YES TEXT d 3 Data transmitter Length Telescope sections 1 1 and IV 1 Fuse b...

Страница 22: ...Solutions www skyazul com 301 371 6126 Note When replacing Transmitter Boards ensure the Link wires are transferred to the same position on the new board Switch connections 10 17 are only used on old...

Страница 23: ...TEXT e 2 Shutdown as radius too large for load Extend telescope sections Compare measured length with the lengths in the lifting capacity table Observe the change on the status display during telesco...

Страница 24: ...3 Slewing Angle Superstructure outside defined Arc permitted by Operation Code entered into CPU Raise or lower Main Boom Angle OR Luffing Jib Angle Return to the defined arc as laid down in the load c...

Страница 25: ...ect connections across WI W2 or W3 if they are required NO Fit or Refit Link wires as per Transmitter board description Pages 8 9 YES 24 volts on Data bus of Transmitter board Terminals 1 2 Fit or Ref...

Страница 26: ...owing voltages present between connections 4 7 With section fully retracted 4 7 0 volt With section fully extended 4 7 2 volt NO With boom fully retracted Adjust Potentiometer to the Zero position ful...

Страница 27: ...er Error Code Text other than those described in this manual contact SkyAzul service with the displayed code the Operation Reeving configuration dialed into the Console and a full description of the a...

Страница 28: ......

Страница 29: ......

Страница 30: ...SkyAz l Equipment Solutions www skyazul com 301 371 6126 SkyAz l Inc 16 Walnut Street Middletown MD 21769 Phone 301 371 6126 Fax 301 371 0029 info skyazul com www skyazul com...

Отзывы: