SkyAzúl,
Equipment
Solutions
www.skyazul.com
301
‐
371
‐
6126
Information
display
shows
letter
d:
TEXT: “d=1"
to “
d=
6"
Voltage supply to all data transmitters
failed; fuse F2 in central unit faulty
Cable to boom unit interrupted
TEXT: “d
=
2"
Data transmitter "Main boom angle"
1.
Fuse blown
2. Terminals
1
and 2 have no contact
1.
Secure plug on back of SU
2. Secure cable connections on
boom unit, particularly terminals
1
and 2 on data transmitter in the
boom unit
1.
Replace fuse
0.16
A (SLI 3) on
data transmitter
2.
Reconnect cable between terminals
1
and 2
NO
YES
YES
NO
Remove SU central unit (remove
4
retaining screws, pull central unit out
of Instrument panel), replace fuse
F2
(1.25 A)
Fuse blown again: Short circuit in
the system
Call SkyAzul
YES
TEXT: "d
=
3"
Data transmitter "Length Telescope
sections
1\1
and IV"
1.
Fuse blown
2. Terminals
1
and 2 have no contact
1.
Replace fuse
0.16
A (SLI 5) on
data transmitter
2.
Reconnect cable between terminals
1
and 2
NO
YES
TEXT: “d
=
5"
Data transmitter ·Pressure derricking
cylinder lower chamber"
1.
Fuse blown
2. Terminals
1
and 2 have no contact
1.
Replace fuse
0.16
A (SLI 6) on
data transmitter
2.
Reconnect cable between terminals
1
and 2
NO
YES
TEXT: “d
=
6"
Data transmitter ·Length
Telescope sections I and II·
1.
Fuse blown
2. Terminals
1
and 2 have no contact
1.
Replace fuse
0.16
A (SLI 4) on
data transmitter
2.
Reconnect cable between terminals
1
and 2
NO
YES
NO
Call SkyAzul 301-748-6057