39
Support Hotline: +49 (0) 2661 98088-112
Support E-Mail: [email protected]
Version No. 2.0
Document No. 97010703
SKS-Kinkel Elektronik GmbH
10006901 BSV2012 Video indoor station hands-free
EN
2.4
Storage and Transport
Transport only in original packaging, store in a dry and cool place.
2.5
Care instructions
Just clean the device unit with a soft cloth, moistened with a mild soap solution. Dry cleaning, aggressive detergents
and abrasives may damage the surface.
2.6
Modification
A modification (alteration or conversion) of the Floor compact power supply is not allowed.
2.7
Safety
Electrical shock hazard to persons. Danger of burns, damage to device and malfunctions.
VDE 0100 and VDE 0800 guidelines must be complied during installation. (Germany)
Counter measures:
3
Before beginning any work, deactivate and disconnect all energized electrical wires.
3
Secure the switched off/disconnected lines against erroneous reconnection.
3
Use a measuring device to make sure that the wires are de-energized.
3
Cover up any adjacent, energized or conducting components.
3
All work and all electrical connections must comply with the national provisions for the country in question and
must be performed by appropriately trained personnel.
Mounting, installation, reparation and initial setup must be carried out by qualified elec
-
tricians only! When working on systems with 230 V alternating voltage the safety require-
ments of DIN VDE 0100 must be complied with.
The SKS planning guide (can be downloaded from www.sks-kinkel.de) must be followed during installation!
3 General information on the 6-wire video BUS
✓
Both the loop resistance towards the indoor stations (GND and +22) as well as that towards the door station
must not be higher than 10 Ω.
✓
The additional length of all cables between door station and main distribution must be 75 m or less, only if a
Video compact power supply with amplifier or an Extended video compact power supply with amplifier is used
the length between distribution and the door station furthest away can be up to 350 m.
✓
The additional length between the indoor station furthest away and the main distribution must not be more than
200 m.
✓
The BUS power has to be between 19 V and 26 V.
✓
For BUS lines and all other functions described twisted wire pairs have to be used. We do recommend to use
cable types J-Y(St)Y and G51 with a wire diameter of 0,8 mm. If needed the shield has to be statically ground
-
ed.
✓
Up to three indoor stations can be configured with the same call address (parallel operation).
✓
When using star wiring or very long lines passive/active distributors are compulsory.
✓
It is possible to realise special functions (e. g. light signal systems, automatic door opening etc.) with additional
switch modules.