DA 3800 Flange Inlet
Mounting Guide
9
433352 DA 3800 inlet funnel
The inlet funnel incl. coarse net is used for retrofitting to improve perfor-
mance as well as avoid the ingress of birds and larger animals.
Inlet funnel contains an insulation piece for insulation.
Click it directly onto the inlet.
One per inlet.
433360 DA 3800 hen net
It is used to prevent the birds from sitting on the inlet flap.
Cannot be used together with the air direction baffle.
It comes with mounting fitting.
The air output is not influenced by the hen net.
One per inlet.
433363 DA 3800 louver kit
Used when retrofitting of Advanced Flow Control (AFC)T, which provides
high pressure stability and optimum airflow from minimum to maximum ven-
tilation, is required. Note that in case of new sale, the following part no.
should be offered instead: 433354 and 433353 with inlet funnel including
louver kit/AFC.
One per inlet.
433381 DA 3800 wall gasket
Used as a gasket between the wall and DA 3800 flange inlet. Can in most
cases replace the manual point process.
To be mounted on the inlet frame.
One per inlet.
433372 DA 3800 damper for flap
Used in areas with a risk of strong gust of wind.
Strong gusts of wind on the leeward side of the building can create a high
negative pressure that can close the inlet flap for a short time. The damper
prevents the sound effect that can occur and disturb the animals in these
cases.
One per inlet.
351585 Tapp. screw 5x30 pan TX25 ZnNi spec.
Used when mounting the DA 3800 and accessories in sandwich walls.