SKOPE Pegasus Vertical Freezer - Integral
Servicing
User Manual
Cleaning
Cabinet
When necessary, wipe both the interior and exterior of the cabinet with a
damp cloth. Ensure the cabinet is disconnected from the mains power
supply before cleaning the cabinet. Periodic cleaning of the condenser coil
is also required.
Condenser
Coil
The condenser coil is situated behind the unit front panel. The condenser
coil
MUST
be kept clean for reliable operation and to minimise power
consumption (a blocked condenser can double power consumption).
To ensure trouble free performance, the condenser coil should be brushed
clean once a month and blown clean by qualified service personnel every
six months.
Over time, dust may accumulate within the condenser that cannot be
removed with a brush. if this occurs, contact SKOPE to arrange for a
SKOPE Authorised Service Agent to clean the condenser with compressed
air.
To access the condenser coil
CAUTION
Disconnect the cabinet from the mains power supply before
cleaning the condenser coil or washing the cabinet.
1. Disconnect the chiller from the mains power supply.
2. Remove the refrigeration
unit front panel from the
cabinet by pulling the
bottom of the panel out to
unclip from the side
panels and then lift the
panel up off the cabinet.
Refitting the front panel is
a reversal of this
procedure.
3. The condenser coil is now
accessible for cleaning
.