32
Servicing
Installation Manual
SKOPE MISA Cool & Freezer Rooms
5
Servicing
Cleaning
Room
Periodically wipe the inside and outside of the room with a damp cloth. Use
neutral or slightly alkaline detergent, and rinse and dry the panels after
cleaning. Isolate the refrigeration unit from the power supply when cleaning
around electrical components.
Condenser
Coil
To ensure trouble-free performance, the condenser coil must be kept clean.
We strongly urge monthly cleaning with a soft brush to remove dust and fluff,
and a thorough cleaning every six months. The condenser coil must be kept
clean for efficient and reliable operation. Always isolate the refrigeration unit
from the power supply when cleaning the condenser coil.
Door
Door Seal
To ensure the room operates correctly and efficiently, the door must close
and seal correctly. To check this, enter the room and shut the door. No light
should filter around the door opening. If light is filtering through, check the
door and gasket for alignment and adjust as necessary (see Door Alignment
and Door lock & Gasket Alignment below).
Door
Alignment
If a door is out of alignment, follow the steps below to realign it.
To realign the door
1. Open the door and
remove the top door hinge
cover.
2. Close the door and loosen
the two adjustment
screws.
3. Move the top of the door left or right as necessary to align correctly.
4. Once the door is correctly aligned, tighten the two adjustment screws and
refit the door hinge cover.