ADJUSTMENT AND CALIBRATION:

SF

3-WAY
VALVE

CHEMICAL INJECTION

CONTROL VALVE

CHEMICAL TO PROCESS
(AS AN EXAMPLE SAY 
4200 PSIG / 289 BAR)

CHEMICAL TO CALIBRATION
BEAKER OR TO CALIBRATION
FLOW METER
(AS AN EXAMPLE SAY 
50 PSIG / 4 BAR)

CHEMICAL
SUPPLY
(AS AN EXAMPLE 
SAY 4500 PSIG / 310
BAR) - MUST BE AT 
LEAST 200 PSI / 14 
BAR HIGHER THAN 
PRESSURE OF THE 
CHEMICAL TO 
PROCESS

The SkoFlo Valve is a pressure independent flow control valve.  Once the valve is set at a desired 
flow rate, that flow rate is maintained even though the pressure conditions upstream and/or 
downstream of the valve may change considerably.

The standard Multi-Point SkoFlo valve is set by manually adjusting the rate adjustment handle.  
When the desired flow rate is set, the valve needs no further adjustment, and the valve remains at 
that fixed flow rate until the rate adjustment handle is turned to a new setting.

The flow rate can be set using a flow meter in the line to the process.  However, a flow meter in this
line must be capable of withstanding the process pressure.  This normally limits the availability of 
this type flow meter.

The most common method of calibrating the SkoFlo Valve is with a 3-way valve and a line to a 
calibration beaker or to a low pressure flow meter.  Once the flow rate is set, the 3-way valve is 
switched to direct the chemical to the process.

Since the SkoFlo Valve flows at the set rate independent of the pressure differential across the 
SkoFlo Valve, the flow rate to the process is the same as the flow rate set using the beaker or flow 
meter.  Overall monitoring of the flows is done by taking inventory of the usage from the supply 
tank.

In the above example, the SkoFlo Valve is set with a differential pressure of 4450 psi / 306 bar 
across the valve.  The flow rate set will remain the same when the chemical is routed to process and 
the SkoFlo Valve has a differential pressure of 300 psi / 21 bar.  Note that the SkoFlo valve  should 
not be operated continuously at differential pressures above 3000 psi / 207 bar.

r:\msoffice\excel\e-mail\o_manuals\SkoFlo sf15000nmfa\sf15000nmfa-manual-a1

Page 4 of 13

Содержание SF15000NMFB

Страница 1: ...protected Pressure Independent Flow Controller SkoFlo Valve Model SF15000NMFB OPERATION AND MAINTENANCE INSTRUCTIONS 2 13 2003...

Страница 2: ...nline filter in the system Generally this is located upstream of the pump Clean chemical and proper filtering is very important A 200 micron size filter is recommended START UP PROCEDURES 1 Open the s...

Страница 3: ...the adjustable Cv section into chamber 2 where the piston and springs are located These springs put a force against the piston based on how much the springs are deflected The spring force against the...

Страница 4: ...wever a flow meter in this line must be capable of withstanding the process pressure This normally limits the availability of this type flow meter The most common method of calibrating the SkoFlo Valv...

Страница 5: ...ction only and could possibly become dislodged The valve will not control flow in the reverse direction Flow Control Industries recommends installation of a check valve in the outlet line from the Sko...

Страница 6: ...d probe to carefully remove the seat See figure III Figure III G Lubricate new seat seal with Parker Super Lube or equivalent Slide seal onto seat holder Install back up ring on low pressure side of o...

Страница 7: ...n assembly into body to clear base plate See Figure V Figure V I Lubricate base o ring with Parker Super Lube or equivalent Place o ring into o ring groove of base Install back up ring on low pressure...

Страница 8: ...que the retainer lock bolt to 10 foot pounds 1 4 kg m 2 Replacing Needle Stem Assembly A Disassemble and reassemble the SkoFlo valve using new seals as described in the Replace Seals section above 3 R...

Страница 9: ...d piston passage chamber is plugged Piston Springs are Install springs in not installed accordance with properly drawing SF 0738 and Figure V Seat or pin worn Replace seat holder or damaged or piston...

Страница 10: ...rotectant to the exterior of the valve The shipping plugs in the INLET and OUTLET should remain in place 2 When storing SkoFlo valves after being in use dismantle thoroughly clean and reassemble Then...

Страница 11: ......

Страница 12: ...hemical Supply System CHEMICAL OUT TO PROCESS Chemical Injection System CHEMICAL TO VALVES Notes 1 Any number of injection points can be served by a single pump and header system The only limitation i...

Страница 13: ...O RING SEAT EPR KALREZ 24 1 SF15000NMFA 30 71001929 BACK UP RING FOR ITEM 23 PEEK 25 1 SF15000NMFA 31 20528 SEAT RETAINER NITRONIC 60 SS 26 1 SF15000NMFA 32 71002969 SNAP RING SEAT 15 7 SS 27 1 SF150...

Страница 14: ...N A Satisfied 1 Product Quality 2 Product Features 3 Reliability 4 After sale support 5 Implementation 6 Delivery Score from 1 Low to 7 High Low N A High 1 2 3 4 5 6 7 Recommend SkoFlo to friend or c...

Отзывы: