background image

Cabling 

The transducer cable should be routed to the transceiver box. Any excess cable should 
be coiled in an area with little electrical noise (i.e. not next to a motor or generator). 
Cables are 40m long as standard.  
The transceiver end of the cable is colour coded, and the transceiver screw terminals 
J503 and J502 are also colour coded. Attach the cables as per diagram p 62 operator 
and installation manual 
 
 

 

 
 
The cable from the transceiver box to the deck unit is connected as per diagram 
below. This cable transmits large quantities of data so should be routed away from 
potential noise sources. This cable is RS 422 with handshaking and should not be 
effected by anything but extreme noise. 
 
(See page 61 of Operator and installation manual) 