Speed

The screen presents speed through water (STW) used for the autopilot, radar and logged on the 

voyage data recorder (VDR). The speed data can also be used for setting limits on the rudder and 

stabilizer wings. It also shows speed over ground (SOG) used as a primary system for speed. Some 

of this information is also available from the GPS systems. By adding an approved gyro heading 

input into the system, together with parameters of the vessel, it is possible for the system to calculate 

the transversal speed at any point of the vessel. This feature known as docking, allows the pilot to 

be sure that both the fore and aft of the vessel are under tight control.

Alarms/Alerts

This system does not contain any alerts, however a power failure relay is available 

Distance

In addition the system shows distance travelled through water, and distance over ground and has 

a resettable daily trip counter. This information is used for service intervals and navigation. Extra 

information is available regarding the sea temperature and tilt of the vessel. Note. The Distance over 

ground measures only when the bottom is within range.

The control unit

The user can operate the system via a touch screen or using an application on the conning unit. 

The displays are intuitive and have a menu system, but also allows the user to click on the screen 

to  adjust  the  relevant  parameters.  Full  setup,  calibration  and  diagnostics  are  available  from  the 

screens. Calibration is performed by a two leg sailing procedure, and once set, should not need 

repeating unless the sensor is moved. 

Maintenance

The system is low maintenance. After initial setup and calibration, the system requires no attention 

except to change alert parameters if required. The sensor is exposed to the water and over time 

some  growth  may  appear. This  can  be  carefully  removed  when  possible,  and  is  normally  not  a 

problem except if the vessel is still for longer periods of time (weeks) in warm waters. The effect of 

this growth is usually seen as the range of the bottom track being reduced.

Diagnostics

The system has comprehensive built in test (BIT) that can be used to analyse the performance of the 

equipment and give a warning if the data is not within specification. It also has inbuilt redundancy in 

some areas, such that even if a failure occurs, it can still give some data. Due to the systems LAN 

network point, it is possible to set up the system for remote diagnostics and upgrade using network. 

In time this will help reduce service visits and increase the probability of first time fix. Inserting a USB 

stick into the electronic unit causes the system to log all the available parameters, and these files 

can be sent to skipper or your service provider to diagnose errors in the system

Содержание CU-M001-21-SA

Страница 1: ...1 Dual Axis Doppler Speed Log System SKIPPER Electronics AS Telephone 47 23 30 22 70 Enebakkveien 150 www skipper no P O Box 151 Manglerud E mail support skipper no 0612 Oslo Norway Co reg no NO 96537...

Страница 2: ...g und mitteilung ihres Inhaltes nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen verpflichten zu schadenersatz Toute communication ou reproduction de ce document toute Exploitat...

Страница 3: ...Electronics AS P O Box 151 Manglerud NO 0612 Oslo Norway Phone 47 23 30 22 70 Fax 47 23 30 22 71 E mail support skipper no SOFTWARE UPDATES AND TECHNICAL SUPPORT Find us on the internet www skipper n...

Страница 4: ...0 Brightness Dimming 10 Press this value kn NM to change to other units 11 Page A Primary Data 12 Page B User selectable 13 Page C Resultant and direction 14 Page D Docking 15 Page E Depth 16 Page 2nd...

Страница 5: ...In addition the following abbreviations are used WT Water track BT Bottom track STW Speed through water SOG Speed over ground TripW TripG Text for trip total through water W and over ground G ECDIS E...

Страница 6: ...puts may show invalid data in this mode Symbolising that the data presented is longitudinal forward or backwards for aft Symbolising the data is transversal port or starboard Symbolising the resultant...

Страница 7: ...tection circuitry transceiver In addition the sensor sends at two frequencies giving accurate values The DL1 part of the system is independant and isolated It also uses 2 beams at a higher frequency p...

Страница 8: ...re intuitive and have a menu system but also allows the user to click on the screen to adjust the relevant parameters Full setup calibration and diagnostics are available from the screens Calibration...

Страница 9: ...ime pages A E all except A can be deactivated Additional an optional page 2 nd system is available for use on DL21 systems to show STW from DL1 part of DL21 Page A Basic Page B Combination Programmabl...

Страница 10: ...ed information Page A is not possible to disable SOG is always on in page A Configuration and enabling of pages is performed in config See Runtime Screen setup Brightness Dimming The brightness can be...

Страница 11: ...ate of turn is connected from an external source the speed will be shown with a symbol when the depth 150m bt this will n ot be sent out of the system as this system is not the source of the data Pres...

Страница 12: ...ta The angle of the movement is shown in the symbol of a vessel with a moving arrow If the system is a DL21 then the information from the DL1 can also be shown on this display as shown above An option...

Страница 13: ...Page B User selectable Options This Screen can be used to display combinations of data either as a vector with large arrows as shown or as a resultant and direction symbol The Information sidebar can...

Страница 14: ...current flows sets This option is default off and can only be turned on if there are a satisfactory number of calibrations 3 If the bottom tracking of the system fails too deep or poor signal and a G...

Страница 15: ...designed to clearly show the speed over ground of the vessel and is particularly useful during docking manouvres and general manouvring If Gyro is connected with a valid ROT signal the system will cal...

Страница 16: ...der for the vessel The average value takes the forward looking beam and calulates the depth at that point and using the meas ured speeds predicts when that point is vertically under the vessel The gra...

Страница 17: ...second DL1 Single axis system communicates internally no ad ditional wiring needed with the DL2 and allows it to display the calibrated speeds from that system The Information on the sidepanel is fro...

Страница 18: ...ality control of data Depth is measured from all beams These beams are slanted at approx 30 degrees and will therefore not measure directly underneath the vessel For this reason they cannot be used as...

Страница 19: ...of the vessel In some cases the vessel may drag water with it and this is compensated by calibration This unit meausres within the first 3 m but if required the sampling volume can be moved out from...

Страница 20: ...Page 20 of 38 2021 06 24 CU M001 User manual CONFIGURATION MENU By pressing the Config button on the top left a set of configuration menus are entered...

Страница 21: ...c unit communication setup DL2 SETUP DL2 sensor vessel specific setup COMMUNICATION SETUP Setup of NMEA input Output AUX SETUP Setup of AUX input output To return back to page A D from Config press BA...

Страница 22: ...n the right it is possible to select the main information to be displayed and the information panels can be changed to show other relevant information More information of the main display options can...

Страница 23: ...d speed changes due to drag are usually linear with speed In most cases a single calibration is adequate however on some vessels more may be required Speed logs are calibrated in the factory to give r...

Страница 24: ...ed speed and GPS SOG if available The table to the right indicates the likely quality of this data The vessel should always have at least one Sea test calibration at a high speed To adjust or to look...

Страница 25: ...s will be incorrect An offset will result in the vessel typically showing too much transversal speed but may also result in speed calibration failing Measuring Installation angle A software measument...

Страница 26: ...peeds Fine adjust Installation angle in software Installation angle offset in the software is recommended to fine adjust the angle inside 10deg Allthough the installation error in the software may be...

Страница 27: ...able is split into five real speed zones It is not possible to calibrate more than one point within each zone It is important that at least one high speed zone is calibrated however the other zones wi...

Страница 28: ...sor is changed or if the calibration data is questioned or deemed low quality by the systems internal control systems See status page The vessel is made to sail a known distance and course in both dir...

Страница 29: ...Leg 1 and Stop Leg 1 at the beginning and end as instructed Turn the vessel and perform Leg 2 along the same line in opposite direction in the same speed If the system has GPS on an input VTG then th...

Страница 30: ...e right If you wish to perform a second calibration at another speed move to the next calibration number and repeat Avg measured STW The Water Speed measured in leg Avg measured SOG The bottom Speed m...

Страница 31: ...e the measured speed as the vessel pitches and rolls Rapid measurements allow the system to compensate for tilt and acceleration The sensor is calibrated at the factory but if the user wishes to use t...

Страница 32: ...ollowing parameters NMEA outputs Communication to the sensor Sensor Receiver functionality Internal voltages Temperature Other internal parameters If it finds an error Press the SKIPPER Logo on the le...

Страница 33: ...oftware set the raw data type to the parameter with problems and press start The system will present the GPS data while this function is in use to prevent interference with navigation This data should...

Страница 34: ...es These pages are password protected to reduce the risk of user error More information of these is available in the Installation manual CU M001 SETUP Display communication setup JB70 SETUP Electronic...

Страница 35: ...es careful calibration in very calm conditions and may require all 5 calibration points activation of options It is possible to activate some options by entering a code number in the DL2 Setup In the...

Страница 36: ...Page 36 of 38 2021 06 24 CU M001 User manual This page is intentionally left blank...

Страница 37: ...2021 06 24 Page 37 of 38 CU M001 User manual This page is intentionally left blank...

Страница 38: ...SKIPPER Electronics AS Telephone 47 23 30 22 70 Enebakkveien 150 www skipper no P O Box 151 Manglerud E mail support skipper no 0612 Oslo Norway Co reg no NO 965378847 MVA...

Отзывы: