6.17 Mount the cartridge
Mount the cartridge
• Remove protective screw (6) from lubri-
cator and keep it for later use.
• Remove closure screw (7) of the
cartridge.
• Eliminate contaminations in the area
around the cartridge and the grease inlet
of the driving unit.
• Turn cartridge (2) into the TLMR by hand
until it stops.
Remove the cartridge
•
Turn used cartridge (2) clockwise out of
the TLMR.
•
Check sealing ring (1.5), replace defective
sealing ring.
• Turn in new cartridge as described and
carry out the reset, if necessary, change
the size of the cartridge.
or
• Turn protective screw (6) into the
lubricator.
• Switch off the TLMR.
Protective screw Fig. 15
Closure screw Fig. 16
Eliminate contamination Fig. 17
Check the seal Fig. 18
Dispose of cartridge Fig. 19