Maintenance, clearing malfunctions, repairs
Yes. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
No for TFG 1.. . . . . . . . . . . . . . . . . . . . .
No for TFG 5.., TFG 9.. . . . . . . . . . . . . .
Hypothesis 1-D:
Only for TFG 1..: Wrong control unit
1
Check the type plate of the control unit.
Finding:
Is the manufacturer SKF Actuation System and is the control unit approved for the TFG?
Yes. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replace control unit
Hypothesis 1-E:
Incorrect useful load
1
Check the type plate of the telescopic pillar.
2
Measure the static or dynamic load.
Finding:
Has the useful load been exceeded (see
Yes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reduce load,
No . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hypothesis 1-F:
Control unit defective
1a
TFG 1..: Carry out the troubleshooting procedure for the SKF control unit.
1b
TFG 5.., TFG 9..: Check that the green operating voltage display lights up, if it does
not, the control unit is defective.
Finding:
Is the control unit faulty?
Yes for TFG 1... . . . . . . . . . . . . . . . . . . . Replace control unit
Yes for TFG 5.., TFG 9.. . . . . . . . . . . . . .
No . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hypothesis 1-G:
Service life exceeded
Finding:
Is the telescopic pillar TFG older than 10 years or has it carried out more than 20,000
double strokes at 400 mm stroke length?
Yes. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
No . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hypothesis 1-H:
Thermo-switch stopped pillar
1a
TFG 1..: Isolate the pillar from the control unit and let the pillar cool down for
approx. 20 minutes.
1b
TFG 5.., TFG 9..: Let the pillar cool down for approx. 20 minutes.
Please note: The pillar can not be operated again until the pillar temperature has
fallen below the switching threshold.