15 Periodic inspections
Monthly inspections
•
Inspect the pressure air regulator and drain it of water.
•
Check the pump’s operation.
•
Check the pump and lubrication system for leaks.
When replacing the barrel (in addition to the above):
•
Clean the grease filter and the filter cartridge and replace them if necessary.
16 Troubleshooting
WARNING
Before addressing the following malfunctions, turn off the power from the control and
pumping centre, isolate the pressurised air supply and depressurise the lubrication line
connected to the pump outlet. Any residual pressure in the system when opening or
disconnecting components may cause components to be thrown or lubricant to spray,
causing injury to people or damage to the environment.
16.1 Malfunctions
In case of a malfunction:
– Check the air pressure and the condition of the air lines.
– Check that the grease filter and the hydraulic lines connected to the pump outlet are not clogged.
– If the problem persists, contact your Oy SKF Ab representative.