![SKF Matrix MAX1 Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/skf/matrix-max1/matrix-max1_installation-operation-and-maintenance-manual_1286980079.webp)
9.1 Malfunction table
9.1.1 Matrix MAX1 and MAX3
M a
lfunction
Possible cause
Repair malfunction
To be repaired by
Linear actuator
doesn’t move
No supply voltage.
Check power supply.
Professional electrician
Lack of plug contact or plug has not been
inserted properly.
Plug contacts:
Device control unit, control of voltage network.
Check control operating element.
Operator
Defective network cable or power plug.
Supply cable and plug of the lines:
Check device control unit, control of voltage
network control operating element for damage,
if necessary replace defective elements.
Professional electrician
Obstacle in the stroke area of the linear
actuator.
Remove all obstacles in the stroke area.
Operator
Incorrect load.
Measure static and dynamic load and compare
Qualified personnel
with information concerning the product label.
If the load capacity is exceeded, check the
nominal load and install stronger actuator if
necessary.
Defective control unit/operating element.
Identification of defect concerning the SKF
control unit; if necessary replace defective
control, operating element.
Qualified personnel
Lifespan of the device is exceeded.
If the actuator is older than 10 years and has
Qualified personnel
performed more than 10 000 double strokes
with a 200 mm hub, the actuator needs to be
replaced.
Linear actuator cannot be set in motion by
Exchange device.
Qualified personnel
any of the above listed measures.
Linear actuator cannot
be lifted
Obstacle in the stroke area of the linear
actuator.
Remove all obstacles in the stroke area.
Operator
Incorrect load.
Remove all loads that are on the elements.
Operator
Defective screw nut.
Exchange device.
Qualified personnel
Significantly reduced speed
Obstacle in the stroke area of the linear
actuator.
Remove all obstacles in the stroke area.
Operator
Incorrect load.
Remove all loads that are on the elements.
Operator
Defective motor, gear or screw nut
Exchange device.
Qualified personnel
Significantly increase of
noises during operation
Obstacle in the stroke area of the linear
actuator.
Remove all obstacles in the stroke area.
Operator
Incorrect load.
Remove all loads that are on the elements.
Operator
Defective motor, gear or
ball screw nut.
Exchange device.
Qualified personnel
79