SKF Lincoln PowerLuber AC2400 Скачать руководство пользователя страница 5

Variable output switch

The variable speed switch permits motor 
speed control, the more the trigger is  
depressed the higher speed of the motor 
and therefore the higher the grease output 
of the gun. 

Double insulation

The electric PowerLuber utilizes a double 
insulated motor design for safety. The dou-
ble insulation eliminates the need for a three 
wire grounded cord. All exposed metal parts 
are isolated from the internal metal motor 
components with a double layer of protec-
tion insulation. Double insulated tools do not 
need to be grounded.

Inspection

Visually inspect for damaged, loose or 
missing parts. 

If tool is worn or damaged, remove from 
service. Contact an authorized service 
center for damage assessment or repair.

Operation

Changing “L” or “H” mode

To change the mode of operation:

General description

Appropriate use

The Lincoln PowerLuber was developed for 
manual lubrication of grease points and  
includes a safety valve, stroke counter, out-
put lever, whip hose with coupler and 6 ft. 

(1,8 m)

 power cord. 

The PowerLuber is driven by a small  

electric motor connected to a three-stage 
planetary gear reducer. The rotary motion  
of the motor is converted into a reciprocat-
ing motion of the plunger through an eccen-
tric and yoke mechanism. The PowerLuber 
is a positive displacement single acting 
pump.

Safety valve

The safety valve (

† fig. 1

) is factory set to 

relieve pressure above 7,000 psi 

(482 bar)

The valve also is an indicator of the bearing 
and lubrication line conditions. If grease 
comes out of the safety valve, it indicates a 
clogged or tight bearing or fitting or line. 
Correct this before continuing lubrication 
with the PowerLuber. 

Stroke counter

The tool is equipped with capability for cali-
bration. This is accomplished by measuring 
(weighing) grease flow output and dividing 
the weight of grease by number of strokes. 
Simply put your thumb on the stroke coun-
ter button (

† fig. 1

) during operation of the 

tool and count. 

Some Original Equipment Manufacturers 

(OEM’s) recommend the exact amount of 
grease to lubricate critical bearings. By 
counting the strokes you will know how 
much grease has been dispensed to  
lubricate the bearing. 

Table 2

 details the 

grease output verse number of strokes.

Output

Stroke count

Output per stroke

10

0.20 oz 

(5,7 g)

15

0.30 oz 

(8,5 g)

20

0.40 oz 

(11,4 g)

Note: Lincoln recommends this feature only on low output/

high pressure mode. 

Do not operate tool if outer casing is 
cracked, chipped or damaged 

Double insulated system is intended 

to protect user from shock resulting 
from a break in the tool’s internal 
insulation.

Observe all normal safety precautions 

to avoid electrical shock.

W A R N I N G

•  “L” (low output/high pressure)
•  “H” (high output/low pressure)

When motor is not running,

 push the red 

lever (

† fig. 1

) until letter “L” or “H” will be 

completely visible in the window. 

In case the 

red lever is not completely shifted/ 
engaged, hold this lever and bump the 
switch to engage gears.

High output is recommended if the tool is 

used to lubricate large bearings not requir-
ing high pressure, beyond 3,000 psi 

(206 bar)

. Also, high output is recommend-

ed if tool is used to refill small reservoirs of 
automatic lubrication systems. 

Low output is recommended if the tool is 

used in construction, agricultural and min-
ing applications and general lubrication.  
Low output will provide the maximum pres-
sure of up to 7,000 psi 

(482 bar)

 the tool is 

capable of producing. 

Prime the PowerLuber after each refill or 

grease cartridge change. Prime the gun  
before using it to lubricate grease points.

To prime, operate the gun until grease 

flows from the hose. Use vent valve 
(

† fig. 1

) to expel air pockets.

!

Notice 

To prevent damage to the gears in 

the transmission, the motor must be 
completely stopped before changing the 
lever to the “L” or “H” (low or high) mode 
of operation.

5

A & 

A HYDRAULIC 

800-992-9898

Содержание Lincoln PowerLuber AC2400

Страница 1: ... manual prior to installation or use of this product Keep manual nearby for future reference Failure to follow instructions and safety precautions may result in death or serious injury DANGER Date of issue April 2014 Form number 404575 Section D7 Page 79C A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 2: ... are doing and use common sense when operating a power tool Do not use a power tool while you are tired or un der the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury 3 2 Use personal protective equipment Always wear eye protection Protec tive equipment such as dust mask non skid safety shoes hard hat or hearing prot...

Страница 3: ... con trolled with the switch is dangerous and must be repaired 4 3 Disconnect the plug from the power source and or the battery pack from the power tool before making any adjustments changing accessories or storing power tools Such preven tive safety measures reduce the risk of starting the power tool accidentally 4 4 Store idle power tools out of the reach of children and do not allow persons unf...

Страница 4: ...d This could damage the motor or cause fire Use only accessories that are recom mended for this model Only accessories that are capable of handling 7 000 psi 482 bar should be used Notice Grease cartridges are not included in this product Service Service must be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel may increase the risk of injury Wh...

Страница 5: ...rease by number of strokes Simply put your thumb on the stroke coun ter button fig 1 during operation of the tool and count Some Original Equipment Manufacturers OEM s recommend the exact amount of grease to lubricate critical bearings By counting the strokes you will know how much grease has been dispensed to lubricate the bearing Table 2 details the grease output verse number of strokes Output S...

Страница 6: ... valve Bulk valve Relief valve discharge hole Relief valve 1230 30 in 762 mm hose 5852 Coupler with cap Power cord 6 ft 1 8 m long High low output sensor Stroke counter 6 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 7: ...ubricant Fig 3 Slowly pull the follower handle back while pushing the grease tube assembly deeper into the lubricant to prevent air pockets from being pulled into the grease tube assembly 4 When the follower rod is fully extended pull it sideways to latch the rod groove into the keyhole slot in the grease tube assembly cap 5 Loosely assemble the pump assembly to the grease tube assembly Release th...

Страница 8: ...e trigger in short bursts to operate gun until trapped air is expelled Disengage the follower rod from the follower by rotating the follower handle Push the follower rod into the grease tube assembly 5 If step 2 fails unscrew the grease tube assembly 3 turns from the pump assembly 6 Exert force on the follower handle until lubricant oozes from the grease tube assembly and pump assembly interface 7...

Страница 9: ...1 3 4 2 5 6 7 8 9 10 11 12 8 14 15 16 18 19 20 17 13 Fig 5 9 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 10: ...Fig 6 5 22 21 23 24 25 36 35 26 27 28 21 34 33 12 32 29 30 31 10 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 11: ...e tube 286090 17 Rod follower kit 286091 18 Coupler cap kit 286093 19 Coupler 5852 20 Flexible hose 30 in 762 mm with gasket 1230 21 Gear set kit 286286 22 Motor plate kit 286155 23 Spring selector 286113 24 Yoke kit 286107 25 Cover pump kit 286106 26 Plunger kit 286109 27 Seal 271889 28 Seal retainer kit 286335 29 Driver assembly 286285 30 Stud kit 286110 31 Roller kit 286111 32 Housing pump with...

Страница 12: ...rease Loss of prime Repeat priming operation Ball check item 34 is not functioning Remove 34 and clean and inspect ball seat area PowerLuber continues to lose prime Air may be trapped in several locations in container after bulk filling Empty grease tube assembly refill and repeat priming instructions Follower may be binding in grease tube assembly Replace grease tube assembly 13 Disassemble greas...

Страница 13: ...ment injectors 85771 85781 Lincoln warrants the SL V Injector series to be free from defects in material and work manship for two 2 years following the date of purchase If an injector model single or replacement is determined to be defective by Lincoln in its sole discretion during this warranty period it will be repaired or replaced at Lincoln s discretion without charge Special limited 5 year wa...

Страница 14: ...This page left intentionally blank 14 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 15: ...This page left intentionally blank 15 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 16: ...ptimizing operational and energy efficiency and reducing total cost of ownership These competence areas include bearings and units seals lubrication systems mechatronics and a wide range of services from 3 D computer modelling to cloud based condition monitoring and asset management services SKF s global footprint provides SKF customers with uniform quality standards and worldwide product availabi...

Отзывы: