SKF Lincoln PowerLuber AC2400 Скачать руководство пользователя страница 4

Tool use and care

•  Do not use the PowerLuber if the switch 

does not turn it on and off. A PowerLuber 
that cannot be controlled with the switch 
is dangerous and must be repaired.

•  Disconnect the plug from the power 

source before making any adjustments, 
changing accessories or storing  
PowerLuber. Such preventive safety 
measures reduce the risk of starting the 
PowerLuber accidentally.

•  Store idle PowerLubers out of the reach of 

children and do not allow persons unfa-
miliar with the PowerLuber or these  
instructions to operate it. PowerLubers 
are dangerous in the hands of untrained 
users.

•  Maintain PowerLubers. Check for mis-

alignment or binding of moving parts, 
breakage of parts and any other condition 
that may affect the PowerLuber’s opera-
tion. If damaged, have the PowerLuber 
repaired before use. 

•  Be sure your power supply agrees with 

the nameplate marking. Voltage decrease 
of more than 10% will cause loss of power 
and overheating. If this tool does not  
operate, check power supply.

•  Do not continue to hold down trigger if 

grease gun is stalled. This could damage 
the motor or cause fire.

•  Use only accessories that are recom-

mended for this model. Only accessories 
that are capable of handling 7,000 psi 

(482 bar)

 should be used.

!

Notice 

Grease cartridges are not  

included in this product.

Service

•  Service must be performed only by  

qualified repair personnel. Service or 
maintenance performed by unqualified 
personnel may increase the risk of injury.

•  When servicing a PowerLuber, use only 

Lincoln replacement parts. Use of unau-
thorized parts may increase the risk of  
injury and will void the warranty.

Specifications

Basic PowerLuber model AC2400

Operating power

120 V AC

Rated current

2 A

Maximum operating pressure

7,000 psi 

(482 bar)

Grease reservoir capacity

14.5 oz 

(411 cm³)

Operating temperature range

0 to 122 °F 

(–18 to 50 °C)

Operating current at

– 1,000 psi 

(69 bar)

1.6 A

– 7,000 psi 

(482 bar)

2.75 A

Lubricant (grease)

Up to NLGI #2

Grease output at 1,000 psi 

(69 bar

) (“L” setting)

3.6 oz/min. 

(106,5 cm³/min)

Grease output per stroke at 1,000 psi 

(69 bar)

 (“L” setting)

0.21 oz 

(0.62 cm³)

Weight

8.2 lbs. 

(3,76 kg)

Accessories

Outlet hose model 1230

Pressure rating

7,500 psi 

(510 bar)

Length of hose

30 in. 

(760 mm)

Models

Sales model

Basic PowerLuber Case

AC2440

AC2400

286240

4

A & 

A HYDRAULIC 

800-992-9898

Содержание Lincoln PowerLuber AC2400

Страница 1: ... manual prior to installation or use of this product Keep manual nearby for future reference Failure to follow instructions and safety precautions may result in death or serious injury DANGER Date of issue April 2014 Form number 404575 Section D7 Page 79C A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 2: ... are doing and use common sense when operating a power tool Do not use a power tool while you are tired or un der the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury 3 2 Use personal protective equipment Always wear eye protection Protec tive equipment such as dust mask non skid safety shoes hard hat or hearing prot...

Страница 3: ... con trolled with the switch is dangerous and must be repaired 4 3 Disconnect the plug from the power source and or the battery pack from the power tool before making any adjustments changing accessories or storing power tools Such preven tive safety measures reduce the risk of starting the power tool accidentally 4 4 Store idle power tools out of the reach of children and do not allow persons unf...

Страница 4: ...d This could damage the motor or cause fire Use only accessories that are recom mended for this model Only accessories that are capable of handling 7 000 psi 482 bar should be used Notice Grease cartridges are not included in this product Service Service must be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel may increase the risk of injury Wh...

Страница 5: ...rease by number of strokes Simply put your thumb on the stroke coun ter button fig 1 during operation of the tool and count Some Original Equipment Manufacturers OEM s recommend the exact amount of grease to lubricate critical bearings By counting the strokes you will know how much grease has been dispensed to lubricate the bearing Table 2 details the grease output verse number of strokes Output S...

Страница 6: ... valve Bulk valve Relief valve discharge hole Relief valve 1230 30 in 762 mm hose 5852 Coupler with cap Power cord 6 ft 1 8 m long High low output sensor Stroke counter 6 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 7: ...ubricant Fig 3 Slowly pull the follower handle back while pushing the grease tube assembly deeper into the lubricant to prevent air pockets from being pulled into the grease tube assembly 4 When the follower rod is fully extended pull it sideways to latch the rod groove into the keyhole slot in the grease tube assembly cap 5 Loosely assemble the pump assembly to the grease tube assembly Release th...

Страница 8: ...e trigger in short bursts to operate gun until trapped air is expelled Disengage the follower rod from the follower by rotating the follower handle Push the follower rod into the grease tube assembly 5 If step 2 fails unscrew the grease tube assembly 3 turns from the pump assembly 6 Exert force on the follower handle until lubricant oozes from the grease tube assembly and pump assembly interface 7...

Страница 9: ...1 3 4 2 5 6 7 8 9 10 11 12 8 14 15 16 18 19 20 17 13 Fig 5 9 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 10: ...Fig 6 5 22 21 23 24 25 36 35 26 27 28 21 34 33 12 32 29 30 31 10 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 11: ...e tube 286090 17 Rod follower kit 286091 18 Coupler cap kit 286093 19 Coupler 5852 20 Flexible hose 30 in 762 mm with gasket 1230 21 Gear set kit 286286 22 Motor plate kit 286155 23 Spring selector 286113 24 Yoke kit 286107 25 Cover pump kit 286106 26 Plunger kit 286109 27 Seal 271889 28 Seal retainer kit 286335 29 Driver assembly 286285 30 Stud kit 286110 31 Roller kit 286111 32 Housing pump with...

Страница 12: ...rease Loss of prime Repeat priming operation Ball check item 34 is not functioning Remove 34 and clean and inspect ball seat area PowerLuber continues to lose prime Air may be trapped in several locations in container after bulk filling Empty grease tube assembly refill and repeat priming instructions Follower may be binding in grease tube assembly Replace grease tube assembly 13 Disassemble greas...

Страница 13: ...ment injectors 85771 85781 Lincoln warrants the SL V Injector series to be free from defects in material and work manship for two 2 years following the date of purchase If an injector model single or replacement is determined to be defective by Lincoln in its sole discretion during this warranty period it will be repaired or replaced at Lincoln s discretion without charge Special limited 5 year wa...

Страница 14: ...This page left intentionally blank 14 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 15: ...This page left intentionally blank 15 A A H Y D R A U L I C 8 0 0 9 9 2 9 8 9 8 ...

Страница 16: ...ptimizing operational and energy efficiency and reducing total cost of ownership These competence areas include bearings and units seals lubrication systems mechatronics and a wide range of services from 3 D computer modelling to cloud based condition monitoring and asset management services SKF s global footprint provides SKF customers with uniform quality standards and worldwide product availabi...

Отзывы: