5
SKF LAGD 400
1. Application
The SKF MultiPoint Automatic Lubricator LAGD 400 is an eight-point lubrication system.
The lubricator can be used with all standard SKF grease types and produces a maximum
pressure of 40 bar (600 psi). The maximum pressure is guaranteed when the total length
of the lubrication tubes does not exceed 5 metres (16 ft).
2. Description
2.1 Identiication of parts
A
feed spring
B
cartridge protection cover
C
locking ring
D
grease outlets (numbered 1 to 8)
E
grease itting nipple
F
display
G
control panel
H
power and alarm connectors
K
mounting bracket
L
follower plate
Figure 1
2.2 Method of operation
During each cycle, an electric motor in the lubricator pre-loads a piston. The piston draws
grease into a cylinder. The piston is released at the end of each cycle and pushes the
grease from the cylinder into the eight channels of the outlet block. The piston dispenses
the same quantity of grease through each channel.
The electric motor is controlled by a microprocessor. The microprocessor controls the
dispense modes and detects blocked lubrication tubes and empty grease cartridges.
2.3 Grease supply
A standard SKF grease cartridge supplies grease to the lubricator. An empty SKF grease
cartridge can be reilled through the grease illing nipple.
Engl
ish
Содержание LAGD 400
Страница 2: ......
Страница 134: ...132 SKF LAGD 400 SKF SKF...
Страница 135: ...133 SKF LAGD 400 1 SKF LAGD 400 SKF 40 Bar 5 2 2 1 A B C D 1 8 E F G H K L 2 2 8 2 3 SKF SKF...
Страница 136: ...134 SKF LAGD 400 2 4 SKF 5 10 2 5 20 8 16 8 G 1 4 8 2 Y 1 1 LGMT 2 0 4 Y...
Страница 138: ...136 SKF LAGD 400 4 4 1 4 2 4 4 100 240V 50 60Hz 24V 40V 30mA...
Страница 139: ...137 SKF LAGD 400 100 240V 1 100 240V 2 240V DC 0V 1 2 3 GND 1 2 4 3 SKF 4 4 4 5...
Страница 140: ...138 SKF LAGD 400 4 5 4 5 1 NLGI 2 4 5 2 SET 50cm 500cm PUMP 19 cm 4 6 G 1 4 G 1 4 SKF LAPN 4 7 10 15 mm 4 1 4 6...
Страница 144: ...142 SKF LAGD 400 6 SKF 6 1 ALARM EMPTY ON OFF 4 3 ON OFF 6 2 SKF 7 SKF SKF 7 1 7 2...
Страница 147: ...145 SKF LAGD 400 9 24V POLO POHI POLO 19V POHI 28V...
Страница 150: ...148 SKF LAGD 400 SKF SKF...
Страница 151: ...149 SKF LAGD 400 1 SKF LAGD 400 SKF 40 600 psi 5 16 2 2 1 A B C D E F G H K L 1 2 2 2 3 SKF SKF...
Страница 152: ...150 SKF LAGD 400 2 4 SKF 5 16 10 32 2 5 20 65 8 16 8 G 1 4 8 2 Y 1 1 LGMT 2 0 4 Y Y...
Страница 154: ...152 SKF LAGD 400 4 4 1 4 2 4 4 AC 100 240 VAC 50 60 DC 24 VDC 40 30...
Страница 155: ...153 SKF LAGD 400 2 AC 100 240 VAC 1 100 240 VAC 2 DC 24 VDC 0 V 1 2 Earth 3 GND 1 2 4 3 SKF 4 4...
Страница 160: ...158 SKF LAGD 400 6 SKF 6 1 ALARM EMPTY ON OFF OFF 4 3 ON OFF 6 2 SKF SKF LGFP 2 7 SKF SKF 7 1 7 2 SKF...
Страница 163: ...161 SKF LAGD 400 9 24 DC POLO POHI POLO 19 POHI 28...
Страница 165: ...163 SKF LAGD 400...
Страница 166: ...164 SKF LAGD 400...
Страница 167: ......