5. Assembly
5
- 15 -
951-150-037-EN
Version 01
Clean the work area/metering device of lu-
bricant contamination.
• Remove the drip pan.
• Activate the centralized lubrication
system.
• Execute several metering device strokes.
The yellow LED on the piston detector
lights up to indicate an active metering
device stroke. On the subsequent metering
device strokes, the signal from the piston
detector must be received by the customer’s
monitoring equipment.
• Check the piston detector signal (yellow
LED lights up).
• Check for correct lubrication volume at
the lubrication points.
See Figure 6
5.3 Conducting initial functional test
For kit version with shielding sleeve
•
During the following installation of
the shielding sleeve, make sure that it is
not damaged by the thread of the piston
detector.
• Slip the shielding sleeve (
9
) over the pis-
ton detector (
8
) until it fits firmly on the
front of the metering device.
• Align the shielding sleeve (
9
) so that the
LED on the piston detector
is visible
(through shielding sleeve bore (
10
))
• Connect electrical connection cable
(provided by customer) (
2
) to the piston
detector (
8
).