![SKF 2340-00000026 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/skf/2340-00000026/2340-00000026_service-manual_1287155011.webp)
EN
4. Technical data
4
- 11 -
951-150-037-EN
Version 01
Electrical data
Design
3-wire DC PNP; 2-wire DC PNP/NPN
Operating voltage
[V]
10-36 DC, supply class 2 per cULus
Rated insulation voltage
[V]
60
Power consumption
[mA]
< 5 (only in 3-wire operation)
Protection class
III
Polarity reversal protection
Yes
Readiness delay time
[ms]
<300
Output function
NO-contact
Voltage drop
[V]
3.5
Minimum load current
[mA]
5
Residual current
[mA]
< 0.8
Current-carrying capacity
[mA]
100
Short-circuit-proof
Yes
Overload-proof
Yes
Switching frequency
[Hz]
10, with damping surface
Ø
4mm to 7 Hz
Protection class
[IP]
IP65 / IP68 / IP69K; with cable box screwed
on properly
Salt mist (EN 60068-2-52 Kb)
Immunity test level 5 (4 test cycles)
Immunity to
magnetic interference fields
mT
< 0.2
L+
1
2/4
L-
4
1
3
2
Connector pin assignment without cable break
protection
2-wire DC PNP/NPN
L+
2/4
1
L-
3
4
1
3
2
Connector pin assignment with cable break
protection
3-wire DC PNP