- 42 -
EN
951-180-074-EN Version
03, last updated
2019 / 07
9. Maintenanc
e, cleaning
WARNING
Risk of death
Fire and explosion hazard from the use of flammable
cleaning agents. Do not use stream-jet equipment /
high-pressure cleaners. This may damage electrical
components.
Do not touch cables or electrical components with wet
or moist hands. Cleaning work on conducting compo-
nents may be performed only by a qualified electrician
on products that have been de-energized.
Wear personal protective equipment.
9.4.1 Cleaning agents
9.4 Cleaning
IMPORTANT NOTE
Only pH-neutral, mild cleaning agents compatible with the materi-
als can be used for cleaning.
Soaps or alkaline cleaning agents cannot be used.
• Thorough cleaning of all surfaces with a moist cloth.
• Clean motor cooling fins and the motor fan.
• Mark and secure wet areas.
• Do not use sharp-edged or sparking tools.
9.4.3 Interior cleaning
Interior cleaning and thus dismantling of the gerotor pump unit is
neither necessary nor permitted as part of maintenance work.
9.4.2 Exterior cleaning
10. Malfunctions, causes, and remedies
WARNING
Explosion hazard
Maintenance and repair work may only be performed
by qualified specialists in maintenance/repair in
potentially explosive atmospheres on products that
have been de-energized.
The work, if not performed by the manufacturer,
must be executed by appropriately qualified staff
and inspected by an “officially recognized competent
person.” Perform work only if there is no potentially
explosive atmosphere.
10.2 Safety measures before maintenance work
The following safety measures must be taken before any repair
work:
○
Prevent access by unauthorized persons.
○
Mark the operating range.
○
Unlock the gerotor pump unit.
○
Lock the gerotor pump unit to prevent it from being restarted.
○
Check to ensure the gerotor pump unit is de-energized.
○
Cover adjacent live parts.
10.1 Prior to beginning troubleshooting
In cases of functional failure, always check whether all technical
specifications have been adhered in the existing operating
conditions.