- 14 -
EN
951-180-074-EN Version
03, last updated 2019 / 07
1. Safety instructions
Residual risk
Remedy
Incorrect mounting position.
- Foreign objects fall into the motor’s air inlet.
○
Install an appropriate canopy over the air inlet.
Electrical shock due to reduced insulation
resistance.
○
Check the insulation resistance at a regular basis.
Electrical shock when connecting the pump
unit.
○
Before connecting the pump unit, de-energize all relevant electrical components. Observe any
discharge times. Electrical connections may only be established by electricians tasked and quali-
fied to do so and in accordance with the terminal diagram.
Lifecycle: Transport, assembly, commissioning, operation, malfunction, troubleshooting, maintenance, servicing, shutdown, disposal
Falling of hoisted parts/tools.
○
Nobody is allowed to be present below hoisted parts. Unauthorized persons must be kept away.
Secure hoisted parts using suitable lifting gear (e.g., belts, straps, ropes).
Falling of inadequately secured parts.
○
Secure parts only to components with a sufficient load-carrying capacity. Observe weights. Ob-
serve specified torques for screw connections. If no torques are specified, use those specified for
screw size for 8.8 screws. See literature from screw manufacturer.
Electric shock due to defective power lead.
○
Inspect power lead for damage.
People slipping due to floor contamination
with lubricant.
○
Caution when connecting the hydraulic connections
○
Promptly apply suitable binding agents and then remove the leaked/spilled lubricant
○
Follow operational instructions for handling the lubricant and contaminated parts
Tearing/damage to lines when installed on
moving machine components
○
Do not install on moving components. if this cannot be avoided, use flexible hose lines.
Tearing/damage to lines when installed on
wearing sports or installed with an exces-
sively small bend radius.
○
Use protection lines or anti-kink coils.
○
If necessary, add strain relief for cables
Lubricant spraying out due to faulty compo-
nent fitting / faulty line connection
○
Use hydraulic screw unions and lines suitable for the indicated pressures. These must be checked
for proper connection and for damage prior to commissioning.
Environmental contamination by lubricant
and wetted parts.
○
Dispose of contaminated parts according to the applicable legal/company rules
Strong heating of the motor
due to a jam.
○
Switch off pump, let parts cool off; remedy the cause.
Personal injury/property damage due to tilt-
ing or falling product due to non-compliance
with specified torques
Adhere to the specified torques. Secure the product only to components with a sufficient load-
carrying capacity. If no torques are specified, use those specified for the screw size for screws of
strength class 8.8.