18
Actual temperature display
Set temperature display
Temperature increase key
Temperature decrease key
Figure 7
Temperature settings: hold down the temperature increase or reduce the temperature of
the key to hold for 3 seconds, in the "set temperature display" in the number will
gradually increase or decrease, in order to set the desired temperature value.
8.4.2.3 The use of hot melt and temperature control
a. This
machine
is
recommended
to
use
the
hot
melt
adhesive,
German
Henkel.Dornsproduction model for KS217 or KS215 edge with hot melt adhesive, in line
with European safety standard non hazardous ingredients.
b. This machine is recommended to use the hot melt adhesive, it is recommended (and
temperature) temperature 190-200℃, sticky at best for machinery, slow running.
Note: when the heating temperature exceeds 250 ℃, hot glue decomposition failure.
c. Note: adhesive hot bath is heated to operating temperature, should be extended 10
minutes to be coated rollers to operating temperature before startup, otherwise it might
damage cots.
d. Users must according to the requirement of edge material selection of suitable
environmental and safety requirements of the hot bath gel, and according to the use
of hot melt adhesive select instructions, in order to avoid a hazard.
e. Users before the hot melt adhesive should carefully read the MSDS of hot melt adhesive,
known as its physical and chemical properties, processing methods of emergency
treatment and waste,.
8.4.3 Adjust the amount of Rubber Cots(Figure 8):
According to the label, the control direction is marked, and the handle is screwed and
transferred to the required amount of glue. Note: the addition amount of glue to add
glue pot depth three divides into two following to prevent fill out excess glue, don't
side with adhesive, prevent glue hasn't melted into the machine, the damage to the
machine. Recommended to stop the machine running, a plus glue, glue to be completely
dissolved over ten minutes before the boot can be.