background image

5

SKANDIA ELEVATOR

!

  WARNING!

• Stop the machinery and turn off electric power before attempting any 

type of assembly, electrical connection or maintenance work.

• Do not start the machinery without the elevator hood and all hatches, 

covers, lids and guards fitted in such a way they can only be opened 

with tools.

• Ensure the back stop and its touch guard are fitted at all times.
• Connections to, from and between machinery must be permanently 

mounted and fully enclosed. If the design of the installation does not 

allow this at an outlet, finish off with a 1 m pipe.

• Ensure the machine is anchored and braced as described in the 

assembly instructions.

!

  IMPORTANT!

• If the machine is being assembled outdoors, the motors and 

transmissions must be fitted with a weather cover.

• If a machine or part thereof in any way needs moving/dismantling, 

follow the directions given in the assembly instructions.

• The machine can be stopped and restarted when full of material but 

this option must not be used for intermittent operation.

• In the event of stoppage in operation, troubleshoot as described in 

these maintenance instructions and ensure the elevator boot is free 

of material before restarting.

• If a short circuit should occur, ensure that the electrical equipment is 

in working order before continuing operation.

• Ensure that the electrical equipment is kept free from dirt, dust, 

moisture and electrostatic charge.

Electrical connection

Incorrect electrical connection may lead to personal injury or damage to the 

conveyor equipment and/or other equipment. It can also cause malfunctions 

or a reduction in capacity. 

!

  WARNING!

• All electrical equipment is to be connected by a qualified electrician. 

See separate connecting directions for electronics.

• The power switch must be permanently mounted and located to allow 

easy access when carrying out maintenance work.

• Ensure that sensors and switches for speed, seed boot hatch, belt 

alignment and explosion relief panel are active when in operation. NB! 

Certain sensors/switches are optional accessories only on certain 

machines.

!

  IMPORTANT!

•Ensure the motor protection is set to the correct ampere setting for the 

motor.

• Read the "Back stop" section in the elevator's assembly instructions 

before test starting the motor for the first time.

Содержание SE 140

Страница 1: ...MAINTENANCE INSTRUCTIONS L I H LINE Elevators ZSA010GB 2020 09 01...

Страница 2: ......

Страница 3: ...ed with your Skandia conveyor equipment for a long time Safety information 4 Safety decals 6 Maintenance 8 General 8 Bearings 8 Plastic wearing surfaces H line 8 Elevator boot 8 Transmission 9 Bucket...

Страница 4: ...nformation is presented and interpreted as follows WARNING Disregarding instructions given in warnings can cause serious personal injury or death IMPORTANT Ignoring the instructions given in important...

Страница 5: ...ppage in operation troubleshoot as described in these maintenance instructions and ensure the elevator boot is free of material before restarting If a short circuit should occur ensure that the electr...

Страница 6: ...s WARNING The machine is supplied with safety decals on delivery They must not be removed or defaced If a safety decal becomes damaged you can order a new one free of charge from Skandia Elevator AB S...

Страница 7: ...ing machinery DEK3120 Warning for moving machinery DEK3010 Warning for dust explosion DEK3130 Warning a maximum of 2 people 200 kg 440 lbs may be on the platform and ladders simultaneously SKANDIA ELE...

Страница 8: ...rings are greased for life and do not require additional lubrication Plastic wearing surfaces H line Check the plastic wearing surfaces in the elevator boot only applies to the new generation H line e...

Страница 9: ...Nord Check the oil level before taking into service and at regular intervals thereafter Change oil every 10 000 operating hours or at least every other year The interval between changes can be double...

Страница 10: ...e bucket belt Belt tensioner in belt join 1 Remove the bucket closest to the belt tensioner 2 Roll off a length of bucket belt from the tensioning pulley Use a ratchet spanner torque wrench in the ten...

Страница 11: ...he bucket belt in the assembly instructions Centre the bucket belt IMPORTANT Ensure the bucket belt is centred on the drive and slatted pulley Check how the bucket belt is running on the drive and sla...

Страница 12: ...he centre Retighten the bolts in the bearing Applies to the new generation SEH If the bucket belt runs to the right of the drive wheel in the elevator head loosen not fully the bolts A 4 pcs and B 6 p...

Страница 13: ...13 SKANDIA ELEVATOR SEI SEH A C B E F New generation SEH A B D F C E...

Страница 14: ...the machines and connections are free from waste that the machines work at the correct speed in relation to the intended capacity See the section Technical specifications that the electrician has conn...

Страница 15: ...ection Technical specifications the position of the splash guard in the elevator head outlet The distance to the bucket mounted immediately after the belt tensioner should be 10 mm If the elevator sto...

Страница 16: ...T Do not try to remove a blockage by repeatedly attempting to restart 3 check with the electrician that the motor has been connected to the correct voltage and that the motor protection is set to the...

Страница 17: ...low for maximum permitted elevator height with standard elevator leg plate thickness The motor must not be larger than recommended for the maximum permitted height either 20 t h 30 t h 40 t h 60 t h 8...

Страница 18: ...200 Rice 700 800 Coffee 350 450 Corn 600 700 Fishmeal 550 600 Peas 600 700 Fish pellets 500 900 Beans 700 800 Powdered lime 800 990 Density table Belt tension Nm Belt tensioner in belt join kW 20 t h...

Страница 19: ...00 3 00 3 00 Plate thickness legs mm 1 25 1 50 1 50 Plate thickness alternative legs mm 2 00 2 00 2 00 Plate thickness inlet hoppers mm 3 00 3 00 3 00 SE 140 140 TVM 20 30 40 60 20 30 40 60 Capacity...

Страница 20: ...inlet hoppers mm 3 00 8 00 Plastic 3 00 8 00 Plastic SEH 63 28 33 80 28 33 200 250 300 400 500 600 Capacity for 750 kg m t h 200 250 300 400 500 600 Capacity m h 266 334 400 533 667 800 Speed Belt spe...

Страница 21: ...s 95 99 rpm 3 1 3 3 m s Slatted pulley diameter mm 500 500 630 Bucket model width JET 180 230 300 Max buckets m belt pcs 8 5 7 4 5 9 Buckets m belt pcs 4 5 6 0 7 5 5 2 6 5 4 0 5 0 5 9 Bucket volume ne...

Страница 22: ......

Страница 23: ......

Страница 24: ...SKANDIA ELEVATOR AB KEDUMSV GEN 14 ARENTORP S 534 94 VARA SWEDEN PHONE 46 0 512 79 70 00 FAX 46 0 512 134 00 INFO SKANDIAELEVATOR COM WWW SKANDIAELEVATOR COM...

Отзывы: