14
Air Adjustment
Amount
of air intake can be subject
to differ depending on ambient environment.
Combustion gas should be visually transparent.
1. Open the plastic cover on the right side.
2. Slightly untighten air adjustment damper using a screw ) and adjust an amount of
air intake manually.
3. Retighten the screw of air adjustment damper
Black Smoke from exhaust flue :
Move air adjustment damper clockwise
Whitish Smoke from exhaust flue :
Move air adjustment damper counter-
clockwise
DO NOT breathe in combustion gas from the exhaust flue.
Moisture Control
Users can spray moisturized steam (wet steam) by opening the moisture control valve.
In the event of cleaning interior surfaces or water sensitive areas, ensure that the moisture
control valve is fully closed to minimize surface moisture.
Using two steam guns with the moisture control valve open continuously may consume
steam faster than what can be replenished. Open the moisture control valve by 1/3 allowing
pressure to build up.