13
LED ICON LEGEND
POWER
WATER
WATER PUMP
FUEL
OFF
SOLID
BLINKING
SOLID or OFF
ALARM BEEPS ONCE
ALARM BEEPS CONTINUOUSLY
Standard Operating Procedure
step
Description
1
Turn on the POWER (EMERGENCY STOP) switch and then turn on the STEAM switch.
You will see one of the following signal indications.
2
POWER and WATER PUMP Indicators are turned to the on position.
The water pump supplies water to the steam vessel.
(Programmed feed-water time: DMF
– 180 sec, EST – 300 sec)
3
When the low water probe sensor detects water level in the steam vessel,
ignition system functions.
4
When the high water probe sensor detects water level in the steam vessel,
water pump stops.
5
When internal pressure reaches the operating pressure (8.5 bar), ignition stops
and steam spraying is ready.
Repeat “Standard Operating Procedure” if users drain water from the steam vessel
completely and resume the operation.