This Ultra Nator

 control and alarm system provides a pre-wired contol panel for an indoor duplex pump application. The Ultra Nator

 

employs two receptacles to accept two 120 VAC pump plugs.

In normal operation pumps will alternate based on the pump switch level. If an alarm condition occurs (top fl oat activates), the alarm 
light and horn turn on. The pump in use will turn off and the other pump will turn on. Pumping will continue until the pump switch 
deactivates (bottom fl oat).

ULTRA NATOR

 System Installation Instructions

ULTRA NATOR

 FEATURES

SJE-RHOMBUS

®

 warrants to the original consumer that this product 

shall be free of manufacturing defects for three years after the date of 
consumer purchase.  During that time period and subject to the conditions 
set forth below, 

SJE-RHOMBUS

®

 will repair or replace, for the original 

consumer, any component which proves to be defective due to defective 
materials or workmanship of 

SJE-RHOMBUS

®

.

THIS WARRANTY DOES NOT APPLY: (A)

 to damage due to lightning 

or conditions beyond the control of 

SJE-RHOMBUS

®

(B)

 to defects or 

malfunctions resulting from failure to properly install, operate or maintain 
the unit in accordance with printed instructions provided; 

(C)

 to failures 

resulting from abuse, misuse, accident, or negligence; 

(D)

 to units which 

are not installed in accordance with applicable local codes, ordinances, 
or accepted trade practices, and 

(E)

 to units repaired and/or modifi ed 

without prior authorization from 

SJE-RHOMBUS

®

.

Some states do not allow limitations on how long an implied warranty 
lasts, so the above limitation may not apply to you.  Some states do not 
allow the exclusion or limitation of incidental or consequential damages, 
so the above limitation or exclusion may not apply to you.  This warranty 
gives you specifi c legal rights, and you may also have other rights which 
vary from state to state.

TO OBTAIN WARRANTY SERVICE:

 The consumer shall assume all 

responsibility and expense for removal, reinstallation, and freight.  Any 
item to be repaired or replaced under this warranty must be returned to 

SJE-RHOMBUS

®

, or such place as designated by 

SJE-RHOMBUS

®

.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS 
ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY.  
SJE-RHOMBUS

®

 SHALL NOT, IN ANY MANNER, BE LIABLE FOR 

ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT 
OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED 
WARRANTY.

  NEMA 1 rated for indoor use.

 

Alternating pump action equalizes pump wear.

  Factory-installed 10ft power cord.

  Factory-installed pump activation and alarm activation switches for easy installations. (Various switch confi gurations available).

  Green power on indicator.

  Green pump run indicators (pump 1 & pump 2).

  Audible and visual high water alarm.

  Normal/silence alarm switch mounted externally for easy operation.

  Entire system is UL and cUL Listed to meet and/or exceed industry safety standards.

   Three-year limited warranty.

SJE-RHOMBUS

®

 THREE-YEAR LIMITED WARRANTY

PREVENTATIVE  MAINTENANCE

•  

Periodically inspect the product. Check that the cable has not become worn or that the housing has not been damaged so as to impair the protection of the  

 

 

product. Replace the product immediately if any damage is found or suspected.

•  

Periodically check to see that the fl oats are free to move and operate the pump and alarm. 

• 

Use only SJE-Rhombus

®

 replacement parts.

Содержание Ultra Nator

Страница 1: ...ion may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state TO OBTAIN WARRANTY SERVICE The consumer shall assume all responsibility and expense for removal reinstallation an...

Страница 2: ... these instructions with warranty after installation This product must be installed in accordance with National Electric Code ANSI NFPA 70 so as to prevent moisture from entering or accumulating within boxes conduit bodies fittings float housing or cable Figure C WARNING Tethering switches below minimum tether length can affect switch operation and will reduce the fatigue life of the cable Figure ...

Страница 3: ...our SJE Rhombus supplier for replacements Figure D Figure E MOUNTING THE VERTICAL REED SWITCH Warning Do not install switch in direct line of incoming liquid 1 Determine desired activation level and pumping range as shown in Figure F Pumping range can be adjusted by moving the float stop up or down the rod 1 Place the clamp into the VRS switch housing as shown in Figure G 2 Locate clamp at desired...

Страница 4: ...__________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ _____________________...

Отзывы: