background image

  8  

 

sent, the alarm will sound again. The alarm silencer (silence mode) can be repeated until the air has been 
cleared of the condition causing the alarm. 

CAUTION:

  Before  using the alarm silence (silence), identify the  source  of the  smoke and  be  certain  a  safe 

condition exists. 

DANGER:

 If the alarm sounds and it is not being tested, it means the unit is sensing smoke. 

THE SOUND OF 

THE ALARM REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.

 

 

Low Battery status: 

An intermittent "chirp" accompanied by a flashing red LED indicates once every 50 seconds indicating that 
the  batteries  have  reached  a  low  voltage.  In  order  to  avoid  noise  to  disturb  your  sleep,  pressing  the  test 
button temporarily silences this warning tone for 10  hours. After the 10 hours it will again prompt you to 
replace the batteries. 
 

WHAT TO DO WHEN THE ALARM SOUNDS: 

1.

 

Alert small children in the home to quickly follow the family escape plan. 

2.

 

Leave immediately  by your escape plan. Every second counts, so don’t waste time getting dressed  or 

picking up valuables. 

3.

 

In leaving, don’t open any inside  door without first feeling  its surface. If 

it  is  hot  or  if  you  see  smoke 

seeping through cracks, don’t open that door! Instead, use your alternate exit. If the inside of the door is 

cool, place your shoulder against it, open it slightly and be ready to slam it shut if heat and smoke rush in. 

4.

 

Stay close to the floor if the air is smoky. Breathe shallowly through a cloth, wet if possible. 

5.

 

Once outside, go to your selected meeting place and make sure everyone is there. 

6.

 

Call the fire department from your neighbor’s home 

-not from yours! 

7.

 

Don’t return to your home until the fire officials say that it is all right to do so.

 

8.

 

There are situations where a smoke alarm may not be effective to protect against fire. For instance: 
a) Smoking in bed 
b) Leaving children home alone 
c) Cleaning with flammable liquids, such as gasoline 

Note:

 These  guidelines will assist you in the  event of a  fire.  However,  to reduce the  chance  that  fires will 

start, practice fire safety rules and prevent hazardous situations. 
 

Trouble shooting: 

DO NOT disconnect batteries to quiet an unwanted alarm.

 This will remove your protection. Fan the air or 

open a window to remove smoke or dust. 

Problem 

Cause and Remedy 

Smoke  alarm  does  not  sound 
when tested. 

1.

 

Activate the smoke alarm before installation. 

2.

 

Clean the smoke alarm. Please refer to the  section 

“maintenance and 

clean

ing”

3.

 

If problems persist and the unit is still under warranty, you can return 
to your retailer. If the unit is out of warranty, please replace it with a 
new alarm. 

Smoke alarm beeps with the red 
LED  flashing  about  once  every 
50 seconds 

The batteries are depleted, please replace them. 

Smoke alarm  chirp  occurs every 
50 seconds (and alarm goes into 
fault mode) 

Clean  the  smoke  alarm. 

Please  refer  to  the  section  “maintenance  and 

cleaning”.

 

Replace smoke alarm if the problem persists. 

Содержание GS559B

Страница 1: ...en the smoke is detected the sensor will send messages to the main controller and then sound the alarm Through the Z Wave network the devices associated can response after smoke is detected for instance start fire extinguishing equipment and trigger an alarm Through the Z Wave network controller you will be notified in case of fire Produkteinführung Deutsche Anleitung siehe ab Seite 10 Das Gerät i...

Страница 2: ... 2 Diagram 1 Bild 1 Diagram 6 Bild 6 Diagram 2 Bild 2 Diagram 4 Bild 4 Diagram 3 Bild 3 Diagram 5 Bild 5 ...

Страница 3: ...rating the product 2 Make sure the alarm is on its final install location and then set the controller into the Add Inclusion mode 3 Quickly triple click the test button the LED will light up 4 Issued beep LED off the alarm being Add included to the network successfully Remove Excluding alarm from Z Wave Network 1 Make sure the battery is installed well before operating the product 2 Set the Z Wave...

Страница 4: ... when the smoke is cleared The alarm will send a BASIC SET 0xFF message to associated group 4 when the heat function is over heat alarm and the alarm will also send a BASIC SET 0x00 message to associated group 4 when the overheat alarm is cleared The maximum number of devices that can be added to the association group 1 is 1 The maximum number of devices that can be added to the association groups...

Страница 5: ... respond to it to reduce the risk of injury or death that may result from fire If a household mem ber is hard of hearing install special smoke alarms with lights or vibrating devices to alert occupants 7 Smoke alarms can only sound their alarms when they detect smoke or detect combustion particles in the air They do not sense heat flame or gas This smoke alarm is designed to give audible warning o...

Страница 6: ... floor plan and multiple floor plan please refer to diagram 2 and diagram 3 If alarm couldn t be installed in the middle of the ceiling for some reasons the distance from the wall corner should be at least 50 cm see diagram 4 If the length of the room or the hall is beyond 30 feet 10m you need to install several alarms in the hall When the ceiling is slanting the alarm needs to be installed 500 mm...

Страница 7: ...action only temporarily silences the chirp Fault indication The chirp will occur between the flashes of the red LED indicator light NOTE When the unit chirps once every 50 seconds pressing the test button temporarily silences this warn ing tone for 10 hours Please refer to section Trouble shooting for solutions If the fault signal reactivates you MUST replace the unit with a new alarm at once or c...

Страница 8: ...rush in 4 Stay close to the floor if the air is smoky Breathe shallowly through a cloth wet if possible 5 Once outside go to your selected meeting place and make sure everyone is there 6 Call the fire department from your neighbor s home not from yours 7 Don t return to your home until the fire officials say that it is all right to do so 8 There are situations where a smoke alarm may not be effect...

Страница 9: ... properly and is still under warranty please return it to the original place of purchase Pack it in a well padded carton and ship to the original place of purchase If the alarm is no longer under warranty please have a licensed electrician replace it immediately with a comparable alarm DEVELOP AND PRACTICE A PLAN OF ESCAPE Install and maintain fire extinguishers on every level of the home in the k...

Страница 10: ...efindet und setzen Sie den Controller in den Modus Hinzufügen Add 3 Drücken Sie den Test Knopf drei Mal schnell hintereinander die LED leuchtet auf 4 Der Rauchmelder wurde erfolgreich zum Netzwerk hinzugefügt wenn ein Signalton ausgegeben wird und die LED ausschaltet Entfernen Remove des Rauchmelders aus dem Z Wave Netzwerk 1 Stellen Sie sicher dass die Batterie des Geräts richtig installiert ist ...

Страница 11: ... classes Siehe Command classes ab Seite 4 Wichtige Sicherheitshinweise 1 Der Testknopf überprüft die Rauchmelder Funktionen verwenden Sie keine andere Testmethode Testen Sie den Rauchmelder wöchentlich um einen ordnungsgemässen Betrieb sicherzustellen 2 Wenn Sie sicher sind dass es sich um einen Fehlalarm handelt öffnen Sie die Fenster oder fächern Sie die Luft um den Rauchmelder herum auf So könn...

Страница 12: ...sdauer der Batterien oder verursa chen Fehlalarme 5 In staubigen schmutzigen oder von Insekten befallenen Bereichen deren Partikel den Betrieb des Rauchwarnmelders beeinflussen Batterie ersetzen siehe Bild 1 1 Drehen Sie den Rauchmelder gegen den Uhrzeigersinn und nehmen Sie ihn aus der Halterung 2 Entfernen Sie die alten Batterien aus dem Batteriefach 3 Stecken Sie die zwei neuen Batterien ins Ba...

Страница 13: ...ücken der Test Taste wöchentlich um den ordnungsgemässen Betrieb sicher zustellen Nach etwa 3 Sekunden ertönt der Alarm wenn die elektronische Schaltung die Hupe und die Batterien ordnungsgemäss funktionieren Wenn kein Alarm ertönt sind eventuell die Batterien erschöpft oder ein anderes Problem liegt vor Lösungen finden Sie im Kapitel Fehlerbehebung Verwenden Sie KEINE offene Flamme um Ihren Alarm...

Страница 14: ...uchmelder wird desensibilisiert indem die Test Taste gedrückt wird Nach ca 10 Minuten wird der Rauchmelder automatisch zurückgesetzt Wenn nach dieser Zeit noch Partikel der Verbrennung vorhanden sind ertönt der Alarm erneut Die Alarmruhe kann wiederholt werden bis die Luft wieder rauchfrei und abgekühlt ist VORSICHT Bevor Sie die Alarmruhe verwenden identifizieren Sie die Rauchquelle und stellen S...

Страница 15: ...hmelder Bitte beachten Sie das Kapitel War tung und Reinigung 4 Wenn das Problem bleibt können Sie das Gerät in der Garantiezeit Ihrem Händler zurückgeben Ausserhalb der Garantiezeit ersetzten Sie das Gerät bitte mit einem neuen Rauchmelder Wartung und Reinigung Zusätzlich zum wöchentlichen Test muss der Rauchmelder regelmässig gereinigt werden um Staub und Schmutz zu entfernen Reinigen Sie den Ra...

Страница 16: ...tial damages for breach of this or any other warranty expressed or implied whatsoever A bad product can be mailed to the address below with a detailed explanation of problem If after reviewing this manual you feel that your smoke alarm is defective in any way please do not tamper with the unit Return it for servicing to manufacturer Garantie Das Unternehmen garantiert dem ursprünglichen Verbrauche...

Отзывы: