Document NO.:RD-519-39-001
Version: A 2018.04.20
- 2 -
reasons. For example, if a fire starts in a remote part of the
home, on another level, in a chimney, wall, roof, or on the
other side of a closed door, smoke may not reach the
smoke alarm in time to alert household members. A smoke
alarm will not promptly detect a fire except in the area or
room in which it is installed.
8.
Smoke alarm may not alert every household member
every time. The alarm horn is loud in order to alert
individuals to a potential danger. However, there may be
some circumstances where a household member may not
hear the alarm (i.e. outdoor or indoor noise, sound sleepers,
drug or alcohol usage, the hard of hearing, etc.). If you
suspect that this smoke alarm may not alert a household
member, install and maintain special smoke alarms.
Household member must hear the alarm’s warning sound
and quickly respond to it to reduce the risk of damage,
injury, or death that may result from fire. If a household
member is hard of hearing, install special smoke alarms
with lights or vibrating devices to alert occupants.
9.
Smoke alarms would activate alarming mode when they
detect smoke or combustion particles in the air. They do
not sense heat, flame, or gas. This smoke alarm is
designed to give audible warning of a developing fire.
However, many fires are fast - burning, explosive, or
intentional, and others are caused by carelessness or safety
hazards. In this circs, Smoke may not remake the unit
alarm
QUICKLY ENOUGH
to ensure safe escape.
10.
Smoke alarms have limitations. This smoke alarm is not
foolproof and is not warranted to protect lives or property
from fire. Smoke alarms are not a substitute for insurance.
Homeowners and renters should insure their lives and
property. In addition, it is possible that the smoke alarm
may fail at any time. For this reason, you must test the
smoke alarm weekly and replace unit after 10 years.
Battery Specification:
Voltage: DC 9V (Alkaline. Carbon Zinc, Lithium battery)
Gold Peak: GP1604S
;(
Carbon Zinc Battery
)
Gold Peak: GP1604A
;
(
Alkaline Battery
)
Raymax : 6LR61
;
(
Alkaline Battery
)
EVE: CR9V/P;
(
Lithium battery
)
Voltage: DC 3V (Lithium battery)
GP Energy: CR123A.
(
Lithium battery
)
Replace Battery:
1: Replace the battery:
①
Remove alarm from the base with screwdriver
(See Diagram 1)
②
Open the battery cover and replace with new battery. (See
Diagram 1)
Diagram 1
Warning: AC power should be turned off at this stage.
2: After you replaced the battery:
①
Close the battery cover,
②
Fit the alarm body on base (See Diagram 2).
Diagram 2
3: Turn on the AC power with the green LED light up. Press
test button to test smoke alarm. The sound pattern is 3 short
beeps pause 1.5 seconds, cycle this pattern till release test
button.Then unit goes into 8 minutes hush mode. During this
period, the RED LED will flash once every 8 seconds. 8
minutes later the alarm go to standby status meanwhile the
red LED flashes once every 32 seconds.
If press the test button, it no sound output. May installation
or operation wrong, you can get helps from the section:
“trouble shooting”.
CAUTION:
Test the smoke alarm for correct operation
using the test facility whenever the battery is replaced.
WARNING: The AC power is danger. When replace
battery, you must make sure the AC power is turned off.
Do Not Install Smoke Alarms in the
Following Places:
1.
In the garage. Products of combustion are present when
you start your automobile.
2.
Less than 50cm from the peak of an “A” frame type
ceiling.
3.
In an area where the temperature may fall below 5
℃
or rise
above 45
℃
, such as garages and unfinished attics.
4.
In dusty areas. Dust particles may cause false alarm or
failure alarm.
5.
In high humidity areas (greater than 93% R.H.). Moisture
or steam can cause false alarms.