HEAT ALARM User’s Manual 

 

Type:    GS401 

 

 

 

 
SPECIFICATION: 

 

Power source: 

                DC9V battery   

 

Battery  specification: 

  9Vdc  Alkaline  or  Carbon  Zinc  Battery-  GOLD  PEAK 

GP1604P, GOLDEN POWER 1604D 

 

Battery Life: 

    at least 1 year.

 

 

Alarm current:   

      <30mA   

 

Standby current: 

  <30uA 

Maximum ambient: 

      50

 

 

Recommended coverage: 

200

 

  Recommended spacing:   

13.5m 

 

Maximum distance from wall: 

7.7m 

 

Alarm sound level:     

    85 Decibels at 3 meters (10ft) 

Locating the alarm

 

Heat alarms are intended to be supplementary to smoke alarms and should be placed 

in areas where smoke alarm cannot be used. 

If  your  dwelling  is  on  a  single  storey,  for  a  minimum  protection  you  should  fit  a 

smoke alarm in a corridor or hallway between the sleeping and living areas, place it as 
near to the living areas as possible and ensure the audible alarm can be heard when the 
bedrooms are occupied. See figure 1 for example/ 

If your dwelling is multi-storey, for minimum protection one smoke alarm should be 

fitted at the bottom  of  the staircase with  further alarms fitted on each upstairs  landing. 
This includes basements but excludes crawl spaces and unfurnished attics. See Figure 2 
for example. 
Note:  for  maximum  protection  smoke  alarms  should  be  fitted  in  every  room  (except 
kitchen,  bathroom  and  garage).  Heat  Alarms  located  in  kitchens,  garages,  boiler  rooms 
etc. within 5.3m (17ft) of potential fire sources. 

Do not fit an heat alarm in the bathroom, shower rooms or other room where the unit 

may be triggered by steam or condensation. 

Positioning the alarms   

mounting(See diagram 1,2) 

 

 

 

 

 

 

     

 

 

 

  On a sloping ceiling

 

In areas with stopping or peaked ceilings install your smoke alarm 900mm from the 

highest point measured horizontally because “dead air” at the apex may prevent   

Areas to be avoided included the following:

 

 

s

ituations where the temperature may fall below 4

 or rise above 44

 

 

Humid areas such as bathrooms, kitchens, shower rooms where the relative humidity 
may exceed 90%. 

 

Near  a decorative object, door,  light fitting,  window molding etc. that may prevent 
smoke or heat from entering the alarm. 

 

Adjacent to or directly about hot components such as radiators or wall vents that can 

 

 

 

 

 