7
ELECTRICAL DATA
AUTOMATIC SHUT-OFF valves
EV1
EV2
Voltage (AC)
Consumption (mA)
Consumption (mA)
Class B o A
Class D o C
240 V 50 Hz
50
25
220 V 50 Hz
40
20
220 V 60 Hz
45
25
24 V 50 Hz
450
210
24 V 60 Hz
450
220
Electrical protection rating
IP 54 using 002 type connectors
IP 54 using 160-type connectors
and screw code 0.960.125
with screw and gasket code 0.960.104
CLASSE B + D
I Family
(d=0.45) Q = 7.5 m
3
/h
∆
p = 5 mbar
II Family
(d=0.6)
Q = 6.5 m
3
/h
∆
p = 5 mbar
III Family
(d=1.7)
Q = 8.1 kg/h
∆
p = 5 mbar
CLASSE B + C
I Family
(d=0.45) Q = 5.3 m
3
/h
∆
p = 5 mbar
II Family
(d=0.6)
Q = 4.6 m
3
/h
∆
p = 5 mbar
III Family
(d=1.7)
Q = 5.8 kg/h
∆
p = 5 mbar
GAS FLOW
Flow Q as a function
of the pressure drop
∆
p
CLASSE A + D
I Family
(d=0.45) Q = 5.1 m
3
/h
∆
p = 5 mbar
II Family
(d=0.6)
Q = 4.4 m
3
/h
∆
p = 5 mbar
III Family
(d=1.7)
Q = 5.5 kg/h
∆
p = 5 mbar
CLASSE A + C
I Family
(d=0.45) Q = 3.7 m
3
/h
∆
p = 5 mbar
II Family
(d=0.6)
Q = 3.2 m
3
/h
∆
p = 5 mbar
III Family
(d=1.7)
Q = 4.0 kg/h
∆
p = 5 mbar
0
5
10
Q [m
3
/h d=0,6 B + D]
4
2
6
8
10
∆
p [mbar]
≤
s
(s)
Pu
Time constant
In correspondence with a step variation
of the control pressure (
∆
Pa),
the outlet pressure (Pu),
reaches the operating value
within 4 second.
Time
4
ENGLISH
Содержание 828 NOVAMIX
Страница 2: ......
Страница 3: ...English GB 11 6 Italiano I Français F 23 18 Deutsch D 29 24 Nederlands NL 35 30 17 12 ...
Страница 4: ......
Страница 36: ......