![Sit 190 Series Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/sit/190-series/190-series_use-and-installation-instructions_1285455007.webp)
4. Supply the pilot flame with ample air that is free of combustion products.
5. Make sure that the pilot flames do not impinge on adjacent parts. Do not impinge the main
burner flame on the pilot burner.
English
Fig. 2
6. Avoid pilot flame exposure to falling scale that could impair ignition of the main burner.
7. Do not expose the pilot flame to drafts that push or pull the pilot flame away from the thermopile
or thermocouple.
ø9
6 10 10
5,2
7/16-27UNS
16
5,2
11
24
16
21 11,511,5
8,5
9,
6
9
•
•11,5
9
68,5
correct
location
wrong
location
wrong
location
Fig. 3