background image

 

11

7. USE 
 

 
This chapter is normally used by the user to 

programme his/her Agrónic Diesel, once the 
connections and the configuration have been done by 
the installer. 

 
 

7.1. MAIN MENU 

 
The main menu is the first thing displayed on the 

screen when the programmer is fed. 

Two letters are displayed at the central part of the 

screen. These letters represent the possible options. 
Use the “+” and ”-“ keys to go from one option of the 
menu to the next one. Use the “C” key to enter the 
sections of the displayed option. 

 

        Example 1.- Main Menu screen 

 

 

 

C O

 

 

 

 
The following table shows the meaning of the 

letters which appear in the main menu. 
 

Table 4 – Main Menu options 

MENU 

FUNCTION 

CO 

Consultation 

P1 

Entry of the values of programme 1 

P2 

Entry of the values of programme 2 

P3 

Entry of the values of programme 3 

P4 

Entry of the values of programme 4 

P5 

Entry of the values of programme 5 

HO 

Change clock time 

AP 

Manual activation or stop of programmes 

AS 

Manual activation or stop of sectors 

 
Press the “C” and “+” keys at the same time to 

go back to the Main Menu from any option.  

Every option of the menu has one or more 

sections. In order to identify these sections, a letter, 
indicating the option we are in, and a number, 
identifying every section of the option, are displayed at 
the left of the screen. If an option has just got one 
section, the code corresponds to the letters of the 
option. 

 
The meaning of every code and its sections are 

going to be explained in detail in the following points 
of the manual. 

 
 
 
 
 

7.2. CONSULTATION (Cx) 

 
At Consultation we can see the general state of 

the programmer (breakdowns, conditional stop, time) 
and, specially, all the information about the evolution 
of the programme which is activated.  

 

Table 5 –Consultation option sections 

CODE  FUNCTION 

C1 

Unit time, breakdown, conditional stop. 

C2 

Time left before the first sector is activated. 

C3 

Time left before the second sector is 
deactivated. 

C4 

Activated inputs. 

C5 

Total time the engine has been working. 

 
Press the “C” key to go from one code to the 

next one. Press the “C” and “+” keys at the same time 
to go back to the main menu.  

 

Code C1: Under normal conditions the unit clock 
time is displayed. If there is a conditional stop, the 
letters “P CO” would be displayed. If there is a 
breakdown in the unit: “EA” will appear. if the 
breakdown comes from input 4; “AA” will appear. If 
the start attempts of the engine have gone by 
without being able to start it (the number of start 
attempts is configurable) and “PA” will be 
displayed if, on starting the engine, it is detected 
that the engine has been started without using the 
programmer or a stop in the engine is detected 
when it should be working. 

When anomalies are displayed on the screen, 

their initials blink.  

 

-  Code C2: It shows, in hours and minutes, the time 

left for the working of the first sector to finish. If the 
programme or sector have been activated 
manually, a spot appears to the left of the time. 

 

       Example 2.- Consultation screen 

C 2     .0 1:1 2 

 

-  Code C3: It shows, in hours and minutes, the time 

left for the second sector to finish. If the 
programme or sector have been activated 
manually, a spot appears to the left of the time. 

 

-  Code C4: It shows the input state, independently of 

the programmed delays for every one of them. The 
input number appears if it is activated and a dash if 
it is not.   

 

-  Code C5: It shows the total number of hours the 

engine has been working. The maximum number is 
9999, after this number it starts again at 0. A spot is 
displayed to the left of this number if the 

Содержание AGRONIC diesel

Страница 1: ...nerators It has got 4 inputs to start stop by external order conditional stop oil pressure gauge or battery charge petrol and securities such as levels pressure gauges cylinder head temperature etc It has also got 6 relay outlets 3 for the start stop and engine ignition and other 3 that can adopt one of the following 7 combinations of outlets 1ª Fertiliser Electropump Breakdown indica tion 2ª Fert...

Страница 2: ... access it The sections of consultation programming change of time manual activation of programmes and manual activation of sectors are accessed from the main menu The values displayed in these sections go with an identifying code To choose an option from this menu press the or keys until the screen shows the code of the desired option Press the C key to enter this option Press the and keys to mod...

Страница 3: ...re 0º C to 45º C 0 5 Kg Parameters programmes It can not be erased Humidity 85 Height 2000 m Pollution Grade II DECLARATION OF CONFORMITY It follows the 89 336 CEE Guidelines for the Electromagnetic compatibility and the 73 23 CEE Guidelines of Low Tension for the Fulfilment of the Product Security The fulfilment of the specifications was demonstrated as indicated in the Official Diary of the Euro...

Страница 4: ...s when the engine is not working and is not lit when it is working If the unit conditions indicate that the engine is working but input 3 is disconnected the engine stops and the programme is deactivated The programmer goes to the consultation code C1 showing the intermittent letters PA on the screen until the C key is pressed If on giving the order of starting to the engine it detects that there ...

Страница 5: ...y open it is connected directly to output 2 If the electrovalve is normally closed it will be connected to outlet 3 With the electrovalve normally open this one is closed during the final time of the working If the electrovalve is normally closed this one is opened at the beginning of the working and closed at the end Outlet 3 Diesel engine ignition It is to be connected to the terminal cable 15 5...

Страница 6: ... essential to put a valid code in this section If there is no valid value the programmer does not accept the petitions of engine starting and the screen blinks constantly Table 1 Outlet configuration Configuration number Outlet number Outlet function 1 4 5 6 Fertiliser Pump Breakdown indication 2 4 5 6 Fertiliser Warm up Breakdown indication 3 4 5 6 Fertiliser Pump Warm up 4 4 5 6 Warm up Pump uni...

Страница 7: ...7 CONFIGURATION 5 CONFIGURATION 6 CONFIGURATION 7 ...

Страница 8: ...hat water is available in the well Detection delay at input 2 Start stop function at input 1 or conditional stop at input 2 Detection delay at input 1 Engine only working if input 1 a programme are activated Options Input s to be used Code 12 Code 13 Code 14 Code 15 On activating input 1 On deactivating input 1 On deactivating input 2 On deactivating input 2 1 The engine only starts and stops by p...

Страница 9: ...ter the number of seconds that have to go by before a change is taken into account at input 1 NO YES The engine starts if there is an activated programme 9 The engine starts by external signal only if a programme is working It stops when this signal ends or by end of programme Connect the external start element to input 1 Enter the number of seconds that have to go by before a change is taken into...

Страница 10: ...ed From 0 to 250 seconds 11 Delay in the detection of engine breakdown indicate the delay in the detection of input 3 in order to detect a breakdown in the oil pressure diesel or in the battery charge petrol From 0 to 250 seconds 12 Delay in the activation of input 1 Start or Start Stop according to code 14 From 0 to 250 seconds 13 Delay in the activation of input 2 Stop or Conditional Stop accord...

Страница 11: ...on about the evolution of the programme which is activated Table 5 Consultation option sections CODE FUNCTION C1 Unit time breakdown conditional stop C2 Time left before the first sector is activated C3 Time left before the second sector is deactivated C4 Activated inputs C5 Total time the engine has been working Press the C key to go from one code to the next one Press the C and keys at the same ...

Страница 12: ...ngine is working it would mean that a programme has not finished yet or a sector has been activated manually Whatever the problem is the new programme is the one which is taken into account not paying any attention to the previous one The 00 00 starting time is not valid Code P4 The duration in hours and minutes of the activation of sector number 1 is to be entered here The maximum time is 23 59 C...

Страница 13: ...gation is the time there must not be fertilisation before the end of the irrigation in order to clean the pipes Configuration code 1 The fertilisation will be started when the fertilisation time plus the post irrigation to finish the irrigation is left If the addition of both times is superior to the irrigation time fertiliser will be injected during the whole irrigation 7 8 STOP Press the C and k...

Страница 14: ...14 8 FUNCTION CHART ...

Отзывы: