4

  

· 

 

User manual | H2O Transmitter

Consult the manual of each sensor for detailed information about its installation and 

connection.

H2O Transmitter

Watertight 

connection 

terminals

Sensor

To guarantee the water-tightness of the 

connections of the wires in the module hose, 
using watertight terminals is recommended. 

The connection through these terminals must 

be made without stripping the cable wires.

The 3M Scotchlok series (www.3m.com); 

ES Caps from TYCO Electronics (www.
tycoelectronics.com); or Cellpack resin splice 

and derivation kits (www.cellpackiberica.
com) can be used as connection elements.

6-wire power supply and current output connection hose:

Power supply and current output

Wire colour

ID

Function

1 sensor

2 sensors 3 sensors

White

0V

- (negative) of power supply

x

x

x

Brown

12V + (positive) of power supply

x

x

x

Green

S1

Output 1: 4 - 20 mA

x

x

x

Yellow

S2

Output 2: 4 - 20 mA

x

x

Grey

S3

Output 3: 4 - 20 mA

x

Sensor connection hose, 6-wire (2 sensors) or 9-wire (3 sensors):

Sensor connection

Wire colour

ID

Function

1 sensor

2 sensors 3 sensors

White

A1

Analogue sensor input 1

x

x

x

Brown

0V

Common sensor power supply

x

x

x

Green

VA1 Sensor 1 power supply

x

x

x

Yellow

A2

Analogue sensor input 2

x

x

Grey

0V

Common sensor power supply

x

x

Pink

VA2 Sensor 2 power supply

x

x

Blue

A3

Analogue sensor input 3

x

Red

0V

Common sensor power supply

x

Black

VA3 Sensor 3 power supply

x

It is recommended that loose cables also be connected with an excess of 3M of 
connector to avoid possible short circuits or from them getting wet.

NOTE 

Содержание 06750001

Страница 1: ...h a sensor Meter Group PHYTOS 31 The transmitter adapts the signals coming from the sensors and generates an output in standard 4 20mA current values From the transmitter itself the number and type of sensors and the soil variety can be configu red by using a Module Reader The transmitter supplies each sensor with the necessary supply voltage depending on the type of sensor configured internally A...

Страница 2: ...onment Height 99 mm Width 65 mm Depth 39 mm Weight approx 0 4 Kg Transmitter box dimensions Transmitter power 12 Vdc with 2x1 5mm2 cable 1 sensor 225 metres 2 sensors 150 metres 3 sensors 100 metres From sensor to transmitter 30 metres 4 20 mA current output 1000 metres Maximum distance This symbol indicates that electrical and electronic equipment should not be disposed of along with household wa...

Страница 3: ...hat is not directly exposed to the sun It is absolutely necessary to keep the box water tight Feed the hose cable through the stuffing box and tighten it as well as you can Do not place the transmitter cables next to power lines Installation Connecting The transmitter is provided with two 1 5m cable hoses that allow you to make different connec tions more easily without the need to access the inte...

Страница 4: ...nd current output Wire colour ID Function 1 sensor 2 sensors 3 sensors White 0V negative of power supply x x x Brown 12V positive of power supply x x x Green S1 Output 1 4 20 mA x x x Yellow S2 Output 2 4 20 mA x x Grey S3 Output 3 4 20 mA x Sensor connection hose 6 wire 2 sensors or 9 wire 3 sensors Sensor connection Wire colour ID Function 1 sensor 2 sensors 3 sensors White A1 Analogue sensor in...

Страница 5: ...ee the following options Consultation Configuration c c Transmitter s general consultation menu where you can view Controller firmware version No Transmitter type depending on the sensor used Consultation of the value in mV that the sensors deliver from input 1 A1 to input 3 A3 Consultation of the 4 20 mA current value being delivered output of 1 to 3 CONSULTATION MENU Configuration menu of the di...

Страница 6: ...ng soil a 0 03 b 1 23E 4 c 7 05E 7 d 0 e 0 f 0 The value in is converted by the transmitter itself to standard 4 20 mA current 800 4000 mV in Agrónic format so that in the controller in question it is necessary to select the Ideal data format according to the type of sensor and type of soil selected It is the responsibility of the user to change the data that characterizes said format PHYTOS 31 Me...

Страница 7: ... ponsibility of the user to change the data that charac terizes said format Sensor format TEROS 10 Parameter Default value No of integers 2 No of decimals 1 Sign no Units Calibration point 1 Real value 800 mV Logical value 00 0 Calibration point 2 Real value 4000 mV Logical value 70 0 TEROS 10 Meter Group The sensor delivers a voltage x mV that the H2O transmitter transforms into VWC Volumetric Wa...

Страница 8: ...R 2247 1 Polígon Industrial C de la Coma 2 25243 El Palau d Anglesola Lleida España Tel 34 973 32 04 29 info progres es www progres es Sistemes Electrònics Progrés S A ...

Отзывы: