background image

1 - GENERAL INFORMATIONS

• 

1.1

Utilising the user guide

The user guide is a fundamental document written by the builder, to be considered an integral part of the central
suction unit.
We recommend storing and keeping the user guide throughout the whole operating life of the suction unit.
The main purpose of the user guide is to provide a correct knowledge of the user mode in order to exploit the
best  performance  and  to  maintain  the  central  suction  unit  at  its  best  working  and  security  conditions.
It is absolutely forbidden to duplicate copy or release totally or part of this user guide without previous written
authorization by TECNOPLUS Srl, owner of the trademark SISTEM-AIR.
The manufacturer reserves the right to improve or modify the user guide and the machine itself at any moment,
without prior notice.

• 

1.2

Communications to the manufacturer

For any communication or request of assistance, we strongly suggest to always providing the following details,
so to correctly identify the central vacuum unit model:
- Central vacuum unit model
- Item code
- Serial number
- Year of manufacturing
- Purchase date
- Purchase place
- Detailed information on the arisen troubles or on the kind of information required
All the technical data related to the central vacuum unit are indicated on the IDENTIFICATION PLATE situated
on the central vacuum unit.

• 

1.3

Identification plate

The identification plate is positioned inside the unit, on frontal side, on the motor protection door, that is positioned
behind the upper door. Remove the upper door in order to see the technical data plate.

It contains the manufacturer name, the model, serial number, year of construction, the electrical tension supply
(V), the frequency (Hz), the electrical absorption (A), the installed power (W).

Wolly2 12/12-V01

2

E

n

g

li

s

h

• 

1.4

Technical Support

In  case  of  need,  exclusively  call  the  Manufacturer  Technical  Service  or  an  authorized  centre  always
specifying  the  technical  data  indicated  on  the  identification  plate  and  the  serial  number  of  the  central
vacuum unit

Manufacturer Assistance Service

Authorized Assistance  Centre

CE compliance data

Manufacturer name

Central vacuum unit model

Serial number

Technical data of the electric motor

____________-___

Type:

 _______

-____

___ V~   __ Hz   _._ A   ____W

Mtr.

    __-_____-__-__

IP44

Содержание 8201.0

Страница 1: ......

Страница 2: ...4 3 Installation spaces 9 4 4 Installation applications 9 4 5 Installation with direct frontal air discharge without pipes net 9 4 6 Installtion with carried air discharge with pipes net 9 4 7 Electri...

Страница 3: ...odel Item code Serial number Year of manufacturing Purchase date Purchase place Detailed information on the arisen troubles or on the kind of information required All the technical data related to the...

Страница 4: ...or replacing cleaning the filter Use only original spare parts Never use the vacuum unit to remove textile stuff big size bits and pieces of any material burning coals or ashes Never vacuum liquids Do...

Страница 5: ...until you put it into service in order to keep the central unit in perfect conditions ATTENTION The packing materials delivered with the central unit are inert solid wastes that must be disposed as p...

Страница 6: ...accessories English 5 Wolly2 12 12 V01 M a n u a le T e c n ic o p e r c e n tr a l i a s p i r a n ti c i v i l i N 1 x N 1 x N 1 x N 1 x N 1 x N 2 x N 1 x N 1 x N 1 x N 1 x N 1 x N 1 x N 1 x N 2 x...

Страница 7: ...different use is strictly forbidden The manufacturer must approve by means of written authorization any alteration or modification of the suction unit to remove a specific material Any use different f...

Страница 8: ...ns Electric box Upper door Upper door Lock Safety filter Dust collection bag Lower door Lower door Centering pins Dust entry Clamps for wall fixing Air ventilation Safety thermic feeler Motor Motor so...

Страница 9: ...echnical features Absorption 1 230 kW 1 3 A 5 6 V dc 12 m3 h 234 12 YES kg 8 0 Technical features N users Max Power supply Frequency Motor power Inlet power supply Max air volume Dust container capaci...

Страница 10: ...he outside installations it s better to choose some areas that are less exposed to sunlight Chose a space far from heat sources burners or radiators Provide spaces for the unit air flow entry and exit...

Страница 11: ...Do not connect the machine to a power line with excessive tension rush ideal tension local voltage 10 Power the low voltage inlet signal with safe very low tension It is requested during the unit inst...

Страница 12: ...hose from the suction inlet The central unit will stop automatically NOTE allow the central vacuum unit a few minutes to stop Wolly2 12 12 V01 11 English 5 1 Starting the central vacuum unit 5 HOW TO...

Страница 13: ...med maintenance According to the accumulated operating time of the central vacuum system it is necessary to carry out maintenance operations in order to keep the central unit always well performing an...

Страница 14: ...so to fit the bag membrane into its slot English 13 Wolly2 12 12 V01 Reassemble the cover verifying that the two tooths fit in to two seats of the unit Verify that the bag doesn t go outside 4 3 Gentl...

Страница 15: ...e dust bag from the aspiration feed Unscrew the locking handle Replace the filter cartridge Reassemble dust bag and cover 14 6 3 Replacement of the filter cartidge Open the lower cover Clean the passa...

Страница 16: ...ntenance or servicing not mentioned and therefore not allowed in the user manual Only qualified providers of the technical assistance service can carry out any maintenance or repair operations The gua...

Страница 17: ...l resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service the shop where you purchased the product your loca...

Страница 18: ......

Отзывы: