background image

4 - INSTALLATION

- ATTENTION -

THE FOLLOWING OPERATIONS MUST BE

CARRIED OUT BY QUALIFIED STAFF

• 

4.1

Safeguards

Here are some main rules to be followed in order to ensure a correct installation inside houses.
Installation must foresee, upstream the central unit, a safety bipolar switch.

• 

4.2

Area of installation

Installation of a central vacuum unit presumes the existence of an aspiration pipe network, installed by qualified
staff that should also have spotted the best location for the central unit fixation template.
In case this was not carried out yet, following are some suggestions for a correct installation.
• If the central suction system has to be installed in multi-storey buildings, the suction unit must be located
at the lowest level of the building.

•  Install it in rooms (balconies, storeroom, etc…) that are protected from humidity and high sudden
changes of temperature.
•  If possibile, in the outside installations it’s better to choose some areas that are less exposed to sunlight.

• Chose a space far from heat sources (burners or radiators).
• Provide spaces for the unit air flow entry and exit.
Foresee the air exhausting point outside the house, in a position that would not cause damage or nuisance to
other buildings.

• 

4.3

Installation spaces

Around the unit, we suggest to leave a minimum free space as indicated in the picture, in order to make
easy  the  maintenance  interventios,  or  repair,  or  dust  collection  bag  change  and,  in  the  meanwhile,  to
favour a right air circulation for the motor cooling.

For any question do not hesitate to contact the Manufacturer Technical Assistance Service.

9

• 

4.4

Installation typologies

• Direct frontal air discharge (without pipes net)
• Carried air discharge (with pipes net)

• 

4.5

Installation with direct frontal air discharge (without pipes net)

See illustrative page attached with the handbook

• 

4.6

Installation with carried air discharge (with pipes net)

See illustrative page attached with the handbook

Wolly2 12/12-V01

E

n

g

li

s

h

200

200

100

100

400

1 m

Содержание 8201.0

Страница 1: ......

Страница 2: ...4 3 Installation spaces 9 4 4 Installation applications 9 4 5 Installation with direct frontal air discharge without pipes net 9 4 6 Installtion with carried air discharge with pipes net 9 4 7 Electri...

Страница 3: ...odel Item code Serial number Year of manufacturing Purchase date Purchase place Detailed information on the arisen troubles or on the kind of information required All the technical data related to the...

Страница 4: ...or replacing cleaning the filter Use only original spare parts Never use the vacuum unit to remove textile stuff big size bits and pieces of any material burning coals or ashes Never vacuum liquids Do...

Страница 5: ...until you put it into service in order to keep the central unit in perfect conditions ATTENTION The packing materials delivered with the central unit are inert solid wastes that must be disposed as p...

Страница 6: ...accessories English 5 Wolly2 12 12 V01 M a n u a le T e c n ic o p e r c e n tr a l i a s p i r a n ti c i v i l i N 1 x N 1 x N 1 x N 1 x N 1 x N 2 x N 1 x N 1 x N 1 x N 1 x N 1 x N 1 x N 1 x N 2 x...

Страница 7: ...different use is strictly forbidden The manufacturer must approve by means of written authorization any alteration or modification of the suction unit to remove a specific material Any use different f...

Страница 8: ...ns Electric box Upper door Upper door Lock Safety filter Dust collection bag Lower door Lower door Centering pins Dust entry Clamps for wall fixing Air ventilation Safety thermic feeler Motor Motor so...

Страница 9: ...echnical features Absorption 1 230 kW 1 3 A 5 6 V dc 12 m3 h 234 12 YES kg 8 0 Technical features N users Max Power supply Frequency Motor power Inlet power supply Max air volume Dust container capaci...

Страница 10: ...he outside installations it s better to choose some areas that are less exposed to sunlight Chose a space far from heat sources burners or radiators Provide spaces for the unit air flow entry and exit...

Страница 11: ...Do not connect the machine to a power line with excessive tension rush ideal tension local voltage 10 Power the low voltage inlet signal with safe very low tension It is requested during the unit inst...

Страница 12: ...hose from the suction inlet The central unit will stop automatically NOTE allow the central vacuum unit a few minutes to stop Wolly2 12 12 V01 11 English 5 1 Starting the central vacuum unit 5 HOW TO...

Страница 13: ...med maintenance According to the accumulated operating time of the central vacuum system it is necessary to carry out maintenance operations in order to keep the central unit always well performing an...

Страница 14: ...so to fit the bag membrane into its slot English 13 Wolly2 12 12 V01 Reassemble the cover verifying that the two tooths fit in to two seats of the unit Verify that the bag doesn t go outside 4 3 Gentl...

Страница 15: ...e dust bag from the aspiration feed Unscrew the locking handle Replace the filter cartridge Reassemble dust bag and cover 14 6 3 Replacement of the filter cartidge Open the lower cover Clean the passa...

Страница 16: ...ntenance or servicing not mentioned and therefore not allowed in the user manual Only qualified providers of the technical assistance service can carry out any maintenance or repair operations The gua...

Страница 17: ...l resources For more detailed information about recycling of this product please contact your local city office your household waste disposal service the shop where you purchased the product your loca...

Страница 18: ......

Отзывы: