Siruba VC008 DVU1-0 Скачать руководство пользователя страница 2

使用前請詳閱本說明書,如果在使用上有任何
疑問,歡迎隨時與本公司聯繫。

Please review the manual carefully before using 
of the controller. Please feel free to contact with 
us if you have any question and comment.
For controller installment and maintenance, 

重要安全聲明

SAFETY INSTRUCTIONS

注意

 :

此 標 示 符 號 表 示 錯 誤 的 機 械 安
裝、操作及保養,恐會導致人員
受傷或機器損壞!

Caution

The warning sign indicates that 
incorrect machine installation, 
operation and maintenance 
may cause personnel injury or 
machine damage!

安裝及維修作業請由專業人員處理。

1.

電機接通電源時請不要把腳放在腳踏板上

2.

本產品需專業人員安裝,調試

3.

嚴禁在通電時打開控制箱與電機端蓋

4.

必須保證系統接地可靠

5.

以下操作請務必斷電

A.

換針、穿線或更換底線時

B.

安裝、拆卸或修理時

C.

翻抬縫紉機時

作業環境要求:

1.

請不要在過潮濕的環境中作業

2.

用戶供電應保持穩定

  AC 210V~240V

3.

用戶使用前必須接地,確保人身安全

4.

不要在過熱地方作業

5.

控制系統與電機不要在強磁高輻射環境中作
業,以免干擾而使系統錯誤

務必使用本公司提供或認可的零部件維修。

Please contact with qualified technician for 
assistance.

1.Do not place your foot onto the pedal when 

connecting to the power source.

2.Installation and trial-run must be done by 

skilled person.

3.Open control box or motor cover under 

electrical power is not permitted.

4.Make sure the earthing system is working well.

5.When doing the following the machine has to 

be disconnected from the power supply.

A.When threading machine, replacing 

needle,bottom thread.

B.When install, dismantle and repair.
C.When turn over the sewing machine.

Environmental Requirements:
1.Please do not work at damp place.
2.The voltage requires being stable (AC 

210V~240V).

3.Must be adequately grounded for safety
4.Do not work at high temperature
5.Do not run motor and control system near to 

ferromagnetic or high-radiance area

All the replacement parts for repairing must be 
provide or approved by supplier.

Содержание VC008 DVU1-0

Страница 1: ...VC008 DVU1 0 DVU1 0 ELECTRONIC CONTROL PARAMETER MANUAL...

Страница 2: ...n and trial run must be done by skilled person 3 Open control box or motor cover under electrical power is not permitted 4 Make sure the earthing system is working well 5 When doing the following the...

Страница 3: ...DEX PAGE PRODUCT INSTRUCTIONS 1 INSTALLATION AND TRIAL RUN DIRECT DRIVE TYPE 5 CONTROL PANEL INSTRUCTION 8 ERROR CODE TROUBLE SHOOTING 12 ENVIRONMENTAL REQUIREMENTS 14 WARRANTY SERVICE 14 ii Introduct...

Страница 4: ...personality truly reflects the concept of mechanical and electrical integration more energy saving high efficiency environmental protection beautiful assembled in one It can be widely applied to a var...

Страница 5: ...A Control system includes control box and speedcontroller Introducefor control panel A P2 Introduction 220V 6P 1 12V 2 12V 20mA...

Страница 6: ...sewing machine accurate needle position Furthermore the modular circuit has Self Protection System when against lower voltage over current over heat etc speedcontroller is realized by the pedal speede...

Страница 7: ...tor is made of rare earth permanent magnet guarantee high power and environmental Exactly needle UP DOWN position due to its built in Hall type sensor and compact design C C Partial demonstration P4 I...

Страница 8: ...and speedcontroller as below figure Using screws mount the Control Box and speedcontroller onto sewing table properly 2 2 Schematic diagram of the installation of direct drive motor P5 Rotor Screw Sc...

Страница 9: ...ing machine axis use the screw picture to fix it then install the synchronizing wheel cover picture 3 Install Moter a According to the above install picture use the screw picture to fix the motor pict...

Страница 10: ...position b According to the above install picture to install the Hand wheel picture use the screw picture to fix Attention the needle stop position and the clearance of Hand wheel and the motor is as...

Страница 11: ...w to enter the parameter method of operation 3 Function of key These two keys are used to adjust speed and parameter modulation 2 To enter the parameter method of operation Example How to change the m...

Страница 12: ...ng speed 200 800 RPM 250 RPM P 05 Speed up And slow 2000 4000 RPM 35000 RPM P 06 Set the seam 0 999 Stitch 0 P 10 Automatic Clearance run run 0 1 S Press the S key when change 0 to 1 0 P 11 Presser fo...

Страница 13: ...0 is interval stitiches P 24 suction action maintain time 50 2000ms 120ms this parameter do not use now P 25 suction full power time 35 1000ms 120ms P 26 the power of suction full power 5 100 80 P 27...

Страница 14: ...e 1 100s 10s the biggest maintain time of the foot presser lifter single time P 38 display time 200 4000RPM display the current motor real speed P 39 display the volt of speed controller 14 1010 195 N...

Страница 15: ...ithout plug 2 Speed wire is broken or contact undesirable Er03 Motor holzer or phase error 1 2 A 3 1 Nine hole plug contact undesirable 2 The motor doesnt pack good 3 Holzer is bad Er04 Locked rotor p...

Страница 16: ...eeds limit value DC220V Er20 Deficiency protection 1 220V AC91V DC130V 110V AC45 5V DC65V 1 The motor drive power supply voltage is too low the 220V power supply voltage is lower than the limit value...

Страница 17: ...and control system near to ferromagnetic or high radiance area 1 Since from the purchase of this product the free 2 year warranty lifetime maintenance During the warranty period any quality problems t...

Страница 18: ...specification and or appearances of the equipment described in this instruction book parts list are subject to change because of modification which will without previous notice VC008 DVU1 0 APR 2020...