P-31
後抬腳啟動時間
back foot presser lifter
start time
0-2000ms
0
後踏延遲啟動壓腳的時間
the time of back step delay
start foot presser
P-32
抬壓腳動作維持時間
foot presser lifter
action maintain time
50-1000ms
160ms
此參數暫時不用
this
parameter do not use now
P-33
抬壓腳全力功率時間
foot presser lifter full
power time
35-1000ms
160ms
P-34
抬壓腳全力功率時功
率
the power when the
foot presser lifter full
power
5-100%
100%
P-35
抬壓腳維持功率
foot presser lifter
maintain power
1-500%
20%
P-36
抬壓腳釋放時間
foot presser lifter
release time
0-120ms
30ms
壓腳釋放時間
the foot presser
lifter release time
P-37
抬壓腳保護時間
foot presser lifter
protection time
1-100s
10s
壓腳單次抬起最大維持時間
the biggest maintain time of
the foot presser lifter single
time
P-38
顯示速度
display time
200-4000RPM
顯示當前電機實際速度
display the current motor real
speed
P-39
顯示速控器電壓
display the volt of
speed controller
14-1010
中點電
壓
195
Neutral
point
volt
顯示當前速控器電壓
0
—
1024
,相當於
0-5V
Display the current speed
controller volt 0-1024, it is
equal 0-5V
P-40
顯示直流母線電壓
display DC buses
voltage
60-500V
320v
當電壓高於
395
會報警,
(
直
流母線電壓
/1.414=
交流母線
電壓
)
when the volt is higher than
395V will alarm,(DC buses
volt/1.414 = AC buses volt )
P-41
過壓保護開關
overload protection
switch
0:
關閉
1:
開啟
0: close 1:start
1
設為
0
關閉過壓報警,設為
1
打開報警,當直流母線電壓超
過
395V
時,報警
Er16
,電機
自動停止運行,報警後當電壓
低於
385v
電機可再次運行
set
“
0
"
is close the overload
alarm, set
“
1
"
is open the
alarm, when DC buses voltage
is over 395 V , will display
Er16, the motor will stop
automatic, when volt is lower
385V, the motor can run.
P11