Siruba VC008 DVU1-0 Скачать руководство пользователя страница 15

故障排除

ERROR CODE & TROUBLE  
SHOOTING

錯誤碼

Error 

code

錯誤內容

Error content

錯誤問題的多種可能

Several possible error problem

Er01

找不到停針位

Can

´

t find the needle 

position

1.

手輪靠的不夠近間隙在

2.5mm

2.

九針插頭接觸不良

3.

電機霍爾壞,要更換電機

4.

手輪上的磁鐵掉落

1. The hand wheel is not close, clearance within 2.5 mm
2. Nine plug contact undesirable
3. Motor holzer bad, to replace the motor
4. The hand wheel magnet in the loss

Er02

開機沒有檢測到調速器

Not detected boot 
speed regulator

1.

調速器插頭沒有插

2.

調速器線斷了或接觸不良

1. Speed control device without plug
2. Speed wire is broken or contact undesirable

Er03

電機霍爾或相位線錯誤

Motor holzer or phase 
error

1.

九針插頭接觸不良

2.

電機沒有安裝好,參照圖

A

3.

霍爾壞

1. Nine hole plug contact undesirable
2. The motor doesn

´

t pack good

3. Holzer is bad

Er04

堵轉保護

Locked-rotor protection

1.

電機超載

2.

電機與電控相連接的四心線接觸不好

3.

電機斷線或壞了

1. The motor overload
2. The motor and the controller connected four hole line contact is 
not good
3. Motor is bad 

Er05

硬體過流保護

Hardware over-current 
protection

1.

電機超載

2.

信號線接觸不好或斷了

3.

主機板壞了

1. The motor overload
2. Line contact is bad or broken
3. Main board is bad

Er07

串口通信逾時錯誤

Serial port 
communication 
timeout error

顯示幕至主機板信號線不良或主機板壞

Display to the system board signal is bad or board is bad

P12

Introduction

Содержание VC008 DVU1-0

Страница 1: ...VC008 DVU1 0 DVU1 0 ELECTRONIC CONTROL PARAMETER MANUAL...

Страница 2: ...n and trial run must be done by skilled person 3 Open control box or motor cover under electrical power is not permitted 4 Make sure the earthing system is working well 5 When doing the following the...

Страница 3: ...DEX PAGE PRODUCT INSTRUCTIONS 1 INSTALLATION AND TRIAL RUN DIRECT DRIVE TYPE 5 CONTROL PANEL INSTRUCTION 8 ERROR CODE TROUBLE SHOOTING 12 ENVIRONMENTAL REQUIREMENTS 14 WARRANTY SERVICE 14 ii Introduct...

Страница 4: ...personality truly reflects the concept of mechanical and electrical integration more energy saving high efficiency environmental protection beautiful assembled in one It can be widely applied to a var...

Страница 5: ...A Control system includes control box and speedcontroller Introducefor control panel A P2 Introduction 220V 6P 1 12V 2 12V 20mA...

Страница 6: ...sewing machine accurate needle position Furthermore the modular circuit has Self Protection System when against lower voltage over current over heat etc speedcontroller is realized by the pedal speede...

Страница 7: ...tor is made of rare earth permanent magnet guarantee high power and environmental Exactly needle UP DOWN position due to its built in Hall type sensor and compact design C C Partial demonstration P4 I...

Страница 8: ...and speedcontroller as below figure Using screws mount the Control Box and speedcontroller onto sewing table properly 2 2 Schematic diagram of the installation of direct drive motor P5 Rotor Screw Sc...

Страница 9: ...ing machine axis use the screw picture to fix it then install the synchronizing wheel cover picture 3 Install Moter a According to the above install picture use the screw picture to fix the motor pict...

Страница 10: ...position b According to the above install picture to install the Hand wheel picture use the screw picture to fix Attention the needle stop position and the clearance of Hand wheel and the motor is as...

Страница 11: ...w to enter the parameter method of operation 3 Function of key These two keys are used to adjust speed and parameter modulation 2 To enter the parameter method of operation Example How to change the m...

Страница 12: ...ng speed 200 800 RPM 250 RPM P 05 Speed up And slow 2000 4000 RPM 35000 RPM P 06 Set the seam 0 999 Stitch 0 P 10 Automatic Clearance run run 0 1 S Press the S key when change 0 to 1 0 P 11 Presser fo...

Страница 13: ...0 is interval stitiches P 24 suction action maintain time 50 2000ms 120ms this parameter do not use now P 25 suction full power time 35 1000ms 120ms P 26 the power of suction full power 5 100 80 P 27...

Страница 14: ...e 1 100s 10s the biggest maintain time of the foot presser lifter single time P 38 display time 200 4000RPM display the current motor real speed P 39 display the volt of speed controller 14 1010 195 N...

Страница 15: ...ithout plug 2 Speed wire is broken or contact undesirable Er03 Motor holzer or phase error 1 2 A 3 1 Nine hole plug contact undesirable 2 The motor doesnt pack good 3 Holzer is bad Er04 Locked rotor p...

Страница 16: ...eeds limit value DC220V Er20 Deficiency protection 1 220V AC91V DC130V 110V AC45 5V DC65V 1 The motor drive power supply voltage is too low the 220V power supply voltage is lower than the limit value...

Страница 17: ...and control system near to ferromagnetic or high radiance area 1 Since from the purchase of this product the free 2 year warranty lifetime maintenance During the warranty period any quality problems t...

Страница 18: ...specification and or appearances of the equipment described in this instruction book parts list are subject to change because of modification which will without previous notice VC008 DVU1 0 APR 2020...