9
(3). Operation procedure to access display zone of the second stage of
【
Parameter
Mode B
】
: (Range of parameter codes: 47
~
122 available for selection in Zone B)
a. If in operation, please turn off the
power switch first.
b. Press and hold P key. Meanwhile, turn on the power switch to access the first
display zone
【
47
】
of display zone
【
Parameter mode B
】
.
c. Subsequently, press P key to select
the parameter code to be set. For
example:
【
78
】
d. Use S key to enter the display zone
of
【
parameter value
】
.
e. After entering this zone, press P key
again to adjust the required value.
f. After adjustment, press S key to
confirm saving.
Note 1. Finally, press S key to return
automatically to the operation
zone of
【
Normal Mode
】
.
Note 2. Following example: Trimming
mode.
.
.