ER-07
顯示幕和主機板通訊超時
Serial communication
timeout
1
:顯示幕連接主機板線連接不良
2
:主機板晶片損壞
1: Connect error between display
panel and mainboard
2: Motherboard chip damage
1
:檢查顯示幕與控制器連接線
2
:檢查控制器是否還可運行,如不能運行
就是控制器損壞
3
:檢查機器旁是否有高頻機器干擾
4
:更換顯示幕
1:Check the connection line between the
display screen and the control box.
2: Check whether the controller run well, if
not, controller damage
3: Check whether there is a high frequency
machine near the machine interference
4: Change the display panel
ER-09
記憶體不良
Memory error
1:
主機板記憶體損壞或不良
1: Memory on mainboard damage
or erro
1
:控制器損壞
1: control box damag
ER-10
光眼控制線路故障
Sensor control line error
1:
顯示幕連接光眼線路不良
1:Connect error between display
paneland sensor
1
:顯示幕損壞
2
:顯示幕背部光眼連接線接觸不良
1: Display panel damage
2: Connect error between display panel and
sensor
ER-15
編碼器故障
The motor board error
編碼器故障
The motor board error
ER-16
過壓
Over load
過壓
Over load
電機驅動電源電壓過高,
220v
電源電壓超過限定
值(
ac310v
),或負載慣性過大導至再生電壓超
過限定值
(dc440v),
或電壓檢測回路故障。
注:(
110v
控制系統電源電壓超過限定值
(
ac155v
),或負載慣性過大導至再生電壓超過
限定值
(dc220v)
。
1. The motor drive power supply voltage is too
high, the 220v power supply voltage exceeds
the limit value(ac310v), or the load inertia is too
large to the regenerative voltage exceeds the limit
value(dc440v), or the voltage detection circuit
fails.
Note:(110v control system power supply voltage
exceeds limit value(ac155v), or load inertia is
too large to regeneration voltage exceeds limit
value(dc220v).
ER-17
A
相電流檢測故障
A current checking error
ER-18
B
相電流檢測故障
B current checking error
ER-19
Ab
相電流檢測故障
A&b current checking error
ER-20
欠壓故障
Less volt error
1.
電機驅動電源電壓過低,
220v
電源電壓低於限定值(
ac91v
),或電機驅動
電源電壓低於限定值(
dc130v
)
,
或電壓檢測回路故障。
注:(
110v
電源電壓低於限定值(
ac45.5v
),
或電機驅動電源電壓低於限定值(
dc65v
))
1. The motor drive power supply voltage is too low, the 220v power supply
voltage is lower than the limit value(ac91v), or the motor drive power supply
voltage is lower than the limit value(dc130v), or the voltage detection circuit
fails.
Note:(110 v power supply voltage is below the limit(ac45.5 V), or motor drive
power supply voltage is below the limit(dc 65v))