background image

4. General Parameter List : 

Press P key 

Initial Value 

Description 

Parameter 

NO.

Function 

Name 

Range 

 

 

2

K

T

 

K

T

001 

HS 

200-6500 spm 

6000 

6000  Maximum sewing speed 

002 

LS 

200-500 spm 

200 

200  Low speed 

003 

SLM 

T/A/OF 

OF 

OF 

Slow start 

004 

200-2000spm 

400 

400  Slow start speed 

005 

SLS 

1-99 stitches 

Stitch of slow start 

006 

SMP 

A/M 

Speed for rear air suction step 

007 

ASE 

0-70 

10 

10 

Rear air suction 

008 

ASP 

ON/OF 

OF 

OF 

Speed for automatic sewing at end 

009 

AS 

200-6500 spm 

4000 

4000  Speed of motor run at automatically 

010 

SEN 

ON/OF 

ON 

ON  Selection of sensor 

011 

IBV 

ON/OF 

ON 

OF 

Selection for top sensor level 

012 

CMS 

0-99 stitches 

Stitch setting for sensor detection 

013 

PSN 

ON/OF 

ON 

ON  Safety device 

014 

SET 

ON/OF 

ON 

ON 

Enter trimming sequence after left the 
sensor

015 

STP 

ON/OF 

ON 

ON  Step reset 

016 

LIN 

ON/OF 

OF 

OF 

Type selection for pedal 

017 

LM 

ON/OF 

ON 

ON  (L) Multi tension release 

018 

MSE 

0-99 

16 

16 

(d) Multi sensor stitches detection 

019 

BSM 

6-18 

12 

12 

The size of the needle selection mode 

020 

BSN 

22-42 

32 

32 

Stitch correction 

021 

AFP 

100-5000ms 

500 

500  (TA) Time for presser foot lifting activate 

022 

FD 

100-2500ms 

100 

100  (TB)Delay time for foot lifter drop down 

023 

AFL 

ON/OF 

OF 

OF 

Foot lifting at motor stop 

024 

FPT 

100-9900ms 

9900 

9900  Full on time foot lifter 

025 

AFT 

100-5000ms 

500 

500  Time setting for foot lifter drop down 

026 

FSA 

YES/NO 

NO 

NO  Factory setting 

027 

FLO 

YES/NO 

NO 

NO  Recovery to factory setting 

028 

TVC 

0-9 

Trimming potential at full hell back the 
pedal 

029 

HHC 

ON/OF 

OF 

OF 

Presser foot lifter selection at half hell 
back the pedal 

030 

FHC 

ON/OF 

OF 

OF 

Function selection at full heel back the 
pedal 

Press S key + Power On 

031 

SAB 

ON/OF 

ON 

ON  Front air suction 

032 

FDS 

0-30 

Stitch for front air suction delay 

033 

FSN 

0-70 

Stitch setting for suction at start 

034 

SAE 

ON/OF 

OF 

OF 

Rear air suction 

035 

BDS 

0-50 

12 

20 

Stitch for rear air suction delay 

036 

RSN 

0-70 

Stitch setting for suction at end 

037 

LFB 

ON/OF 

OF 

OF 

Front thread releases 

038 

LFD 

0-30 

Stitch for front thread release delay 

039 

FLS 

0-20 

Stitch setting for thread release at start 

040 

LFE 

ON/OF 

OF 

OF 

Rear thread release 

041 

LPS 

0-3 

Stitch setting for thread release close 
earlier 

042 

LSE 

0-70 

12 

20 

Stitch setting at thread release delay at 
end

043 

LES 

0-70 

Rear tension release stitches setting 

044 

TCB 

ON/OF 

ON 

ON  Front cutter function selection 

045 

FKN 

1-20 

Front cutter number of times 

046 

FDT 

100-2000ms 

100 

200  Front cutter link air saving 

047 

FDN 

0~99 

Stitches between sensor detected and 

front tape cutter activated 

Initial Value 

Parameter 

NO.

Function Name 

Range 

TK 

TK2 

Description 

048 

TCE 

ON/OF 

ON 

ON 

Tape cutter for rear step 

049 

RKN 

1-20 

Number of time for rear tape cutter 

050 

RDT 

0-2000ms 

300 

100 

Interval time for rear tape cutter stop to air 
suction stop 

051 

RDN 

0-99 

stitches between sensor detected and rear 
tape cutter activated 

052 

KCT 

10-990ms 

50 

50 

Time setting for tape cutter 

053 

KDT 

10-990ms 

50 

50 

Tape cutter interval delay time 

054 

MTC 

ON/OF 

OF 

OF 

Manual tape cutter 

055 

KLM 

ON/OF 

ON 

ON 

Tape cutter link air suction 

056 

KST 

0-990ms 

10 

10 

Time  setting  for  air  suction  before  tape 
cutter activated 

057 

KET 

0-990ms 

100 

100 

Time setting for air suction stop after tape 
cutter activated 

058 

WSN 

0-99 stitches 

10 

10 

Interval stitch for indirect air suction 

059 

WST 

100-2500ms 

1-250 stitches 

(MAC=TK) 

Time setting for indirect air suction 

060 

FCS 

OF/NS/WS 

WS 

WS  Heal balk to cancel unfinished step 

061 

ADT 

0~2500ms 

Delay  time  for  air  suction  after  the  step 
finished 

062 

FSM 

OF / A / M 

OF 

OF 

Militia-step function selection 

063 

FS1 

0-999 stitches 

Reserved 

064 

FS2 

0-999 stitches 

Reserved 

065 

SMN 

0-20 stitches 

Middle speed stitches setting 

066 

500-3000 spm 

3000

3000 Middle speed 

067 

FTC 

ON/OF 

ON 

ON 

Sensor function ,  If sewing machine run 

after sensor covered at the start seam. 

068 

FTP 

M/A 

Type selection for foot lifting solenoid 

069 

FO 

0-990 ms 

350 

350  Full-on time setting for foot lifting solenoid 

070 

FC 

10-75% 

40 

40 

Duty cycle time setting for foot lifting 

solenoid 

Press S key + Power On 

Initial Value 

Parameter 

NO.

Function Name

Range 

TK 

TK2 

Description 

071

MAC 

TK/TK2 

TK 

TK2 

Machine code 

072

 

F

 

F

 

F

N

I

INF Input function Select 

073 

INL 

NOP/PT/OP/ 

TK/TK1/KSA/ 

KSM/F/S6 

S6 

NOP

INL Input function Select 

074

NOP 

--- 

--- 

--- 

--- 

075

DIR 

CW/CCW 

CW 

CW 

Direction of motor rotation 

076

DD 

ON/OF 

ON 

ON 

Direct drive or belt drive 

077

NUD 

UP/DN 

UP 

UP 

Selection of needle position 

078

SIN 

0/2 

Single positioning signal   

synchronizer 

079

NU 

L/H 

Define the UP positioning signal 

mode H/L 

080

NOP 

--- 

--- 

--- 

---

081

NOP 

--- 

--- 

--- 

--- 

082

DVM 

EFK/PEG 

PEG

PEG 

Type of thread release 

083

SFM 

NC/NO 

NC 

NC 

Safety switch 

084

ML 

ON/OF 

ON 

ON 

Motor running function selection 

(MLL output) 

085

FLW 

ON/OF 

OF 

OF 

Full heeling pedal with ASL / ASW 

function 

Press S key + Power On 

Initial Value 

Description 

Parameter 

NO.

Function

Name 

Range 

 

 

2

K

T

 

K

T

086

 t

u

p

n

B

N

I

 

T

P

 

T

P

 

B

N

I

087

 t

u

p

n

1

N

I

 

K

T

 

K

T

 

1

N

I

088

IN2

NOP/PT/OP/ 

TK/TK1/KSA/ 

KSM/F/S6 

S6 

NOP 

IN2 input 

089

 t

u

p

t

u

o

 

A

O

 

K

T

 

K

T

 

A

O

090

 t

u

p

t

u

o

 

B

O

 

L

C

N

 

L

C

N

 

B

O

091

 t

u

p

t

u

o

 

C

O

 

W

S

A

 

W

S

A

 

C

O

092

 t

u

p

t

u

o

 

D

O

 

P

O

N

 

P

O

N

 

D

O

093

 t

u

p

t

u

o

 

1

O

 

P

O

N

 

P

O

N

 

1

O

094 

O2 

NOP/TK/OP/ 

OM/ML/NCL/ 

NCW/ASL/ 
ASW/MLL/ 

OP1/TOE 

ASW 

ASW 

O2 output 

095 

TM1 

1-250 

20 

20 

Time setting for motor run 
automatically at on 

096 

TM2 

1-250 

20 

20 

Time setting for motor run 
automatically at off 

097 

UTD 

ON/OF 

OF 

OF 

Motor run automatically 

098 

VER 

--- 

--- 

--- 

Software version 

4.1. Shortcut For Parameter Setting

Key for act or close multi fabric joint together. 
Press and hold 2 seconds to enter [C1 01]

 

to set how many pieces fabric to joint.

Press lightly to select

 

[C1 xx ~ C5 xx]

 

circulation. 

Value increment / decreasing. 

1

Value saving, escape the display. 

To act or close presser foot lifting. 
Press and hold 2 seconds to enter {AFP} parameter setting. 
Select { AFP~ESS } related parameter cycle by tap. 

Value increment / decreasing. 

2

Value saving, escape the display. 

To act or close front air suction/front tape cutter. 
Press and hold 2 seconds to enter {FDS} parameter setting. 
Select { FDS~I1V } related parameter cycle by tap. 

Value increment / decreasing. 

3

Value saving, escape the display. 

To act or close rear air suction/rear tape cutter. 
Press and hold 2 seconds to enter {BDS} parameter setting. 
Select { BDS~RDN } related parameter cycle by tap. 

Value increment / decreasing. 

4

Value saving, escape the display. 

 

To act or close sensor. 
Press and hold 2 seconds to enter {SMP}. 
Select { SMP~STP } related parameter cycle by tap. 

 

Value increment / decreasing. 

5

 

Value saving, escape the display. 

 

Display count or not available 

[TKN]press and hold 2 seconds to enter TKN 

 

Incremental value/Diminished; by manual 

6

 

Value stored and escape , press and hold for 2 seconds to reset 

5. Basic Troubleshooting 

 

n

o

it

u

l

o

s

 

d

n

a

 

n

o

it

i

d

n

o

C

 

 

m

e

l

b

o

r

p

 

e

h

f

o

 

e

s

u

a

C

 

e

d

o

c

 r

o

rr

E

E.4

1. When power on, higher power voltage has been 

  detected. 

2. Connect to a wrong AC power source. 

  Motor and machine will be shutting down. 

  Please check the AC power source. 

E.7

1. Bad connection to the motor connector. 

2. Synchronizer (sensor) signal error. 

3. Machine locked or object stuck in the motor pulley. 

4. Sewing material is too thick. 

Motor and machine will be shutting down. 

Please check the synchronizer (sensor) and its signal. 

Please check machine head to see if any objects stuck in the 

motor pulley, or machine does not rotate smoothly. 

E.P

  Power on, speed control unit is not at neutral position.

Speed control unit return to neutral. 

6. 7-Segment Display Characters Compare Table 