4. General Parameter List :
Press P key
Initial Value
Description
Parameter
NO.
Function
Name
Range
2
K
T
K
T
001
HS
200-6500 spm
6000
6000 Maximum sewing speed
002
LS
200-500 spm
200
200 Low speed
003
SLM
T/A/OF
OF
OF
Slow start
004
S
200-2000spm
400
400 Slow start speed
005
SLS
1-99 stitches
2
2
Stitch of slow start
006
SMP
A/M
M
M
Speed for rear air suction step
007
ASE
0-70
10
10
Rear air suction
008
ASP
ON/OF
OF
OF
Speed for automatic sewing at end
009
AS
200-6500 spm
4000
4000 Speed of motor run at automatically
010
SEN
ON/OF
ON
ON Selection of sensor
011
IBV
ON/OF
ON
OF
Selection for top sensor level
012
CMS
0-99 stitches
3
3
Stitch setting for sensor detection
013
PSN
ON/OF
ON
ON Safety device
014
SET
ON/OF
ON
ON
Enter trimming sequence after left the
sensor
015
STP
ON/OF
ON
ON Step reset
016
LIN
ON/OF
OF
OF
Type selection for pedal
017
LM
ON/OF
ON
ON (L) Multi tension release
018
MSE
0-99
16
16
(d) Multi sensor stitches detection
019
BSM
6-18
12
12
The size of the needle selection mode
020
BSN
22-42
32
32
Stitch correction
021
AFP
100-5000ms
500
500 (TA) Time for presser foot lifting activate
022
FD
100-2500ms
100
100 (TB)Delay time for foot lifter drop down
023
AFL
ON/OF
OF
OF
Foot lifting at motor stop
024
FPT
100-9900ms
9900
9900 Full on time foot lifter
025
AFT
100-5000ms
500
500 Time setting for foot lifter drop down
026
FSA
YES/NO
NO
NO Factory setting
027
FLO
YES/NO
NO
NO Recovery to factory setting
028
TVC
0-9
0
0
Trimming potential at full hell back the
pedal
029
HHC
ON/OF
OF
OF
Presser foot lifter selection at half hell
back the pedal
030
FHC
ON/OF
OF
OF
Function selection at full heel back the
pedal
Press S key + Power On
031
SAB
ON/OF
ON
ON Front air suction
032
FDS
0-30
0
0
Stitch for front air suction delay
033
FSN
0-70
6
6
Stitch setting for suction at start
034
SAE
ON/OF
OF
OF
Rear air suction
035
BDS
0-50
12
20
Stitch for rear air suction delay
036
RSN
0-70
5
5
Stitch setting for suction at end
037
LFB
ON/OF
OF
OF
Front thread releases
038
LFD
0-30
0
0
Stitch for front thread release delay
039
FLS
0-20
1
1
Stitch setting for thread release at start
040
LFE
ON/OF
OF
OF
Rear thread release
041
LPS
0-3
0
0
Stitch setting for thread release close
earlier
042
LSE
0-70
12
20
Stitch setting at thread release delay at
end
043
LES
0-70
0
0
Rear tension release stitches setting
044
TCB
ON/OF
ON
ON Front cutter function selection
045
FKN
1-20
1
1
Front cutter number of times
046
FDT
100-2000ms
100
200 Front cutter link air saving
047
FDN
0~99
7
7
Stitches between sensor detected and
front tape cutter activated
Initial Value
Parameter
NO.
Function Name
Range
TK
TK2
Description
048
TCE
ON/OF
ON
ON
Tape cutter for rear step
049
RKN
1-20
1
1
Number of time for rear tape cutter
050
RDT
0-2000ms
300
100
Interval time for rear tape cutter stop to air
suction stop
051
RDN
0-99
5
5
stitches between sensor detected and rear
tape cutter activated
052
KCT
10-990ms
50
50
Time setting for tape cutter
053
KDT
10-990ms
50
50
Tape cutter interval delay time
054
MTC
ON/OF
OF
OF
Manual tape cutter
055
KLM
ON/OF
ON
ON
Tape cutter link air suction
056
KST
0-990ms
10
10
Time setting for air suction before tape
cutter activated
057
KET
0-990ms
100
100
Time setting for air suction stop after tape
cutter activated
058
WSN
0-99 stitches
10
10
Interval stitch for indirect air suction
059
WST
100-2500ms
1-250 stitches
(MAC=TK)
5
5
Time setting for indirect air suction
060
FCS
OF/NS/WS
WS
WS Heal balk to cancel unfinished step
061
ADT
0~2500ms
0
0
Delay time for air suction after the step
finished
062
FSM
OF / A / M
OF
OF
Militia-step function selection
063
FS1
0-999 stitches
0
0
Reserved
064
FS2
0-999 stitches
0
0
Reserved
065
SMN
0-20 stitches
0
0
Middle speed stitches setting
066
M
500-3000 spm
3000
3000 Middle speed
067
FTC
ON/OF
ON
ON
Sensor function , If sewing machine run
after sensor covered at the start seam.
068
FTP
M/A
M
M
Type selection for foot lifting solenoid
069
FO
0-990 ms
350
350 Full-on time setting for foot lifting solenoid
070
FC
10-75%
40
40
Duty cycle time setting for foot lifting
solenoid
Press S key + Power On
Initial Value
Parameter
NO.
Function Name
Range
TK
TK2
Description
071
MAC
TK/TK2
TK
TK2
Machine code
072
F
F
F
N
I
INF Input function Select
073
INL
NOP/PT/OP/
TK/TK1/KSA/
KSM/F/S6
S6
NOP
INL Input function Select
074
NOP
---
---
---
---
075
DIR
CW/CCW
CW
CW
Direction of motor rotation
076
DD
ON/OF
ON
ON
Direct drive or belt drive
077
NUD
UP/DN
UP
UP
Selection of needle position
078
SIN
0/2
0
0
Single positioning signal
synchronizer
079
NU
L/H
L
L
Define the UP positioning signal
mode H/L
080
NOP
---
---
---
---
081
NOP
---
---
---
---
082
DVM
EFK/PEG
PEG
PEG
Type of thread release
083
SFM
NC/NO
NC
NC
Safety switch
084
ML
ON/OF
ON
ON
Motor running function selection
(MLL output)
085
FLW
ON/OF
OF
OF
Full heeling pedal with ASL / ASW
function
Press S key + Power On
Initial Value
Description
Parameter
NO.
Function
Name
Range
2
K
T
K
T
086
t
u
p
n
i
B
N
I
T
P
T
P
B
N
I
087
t
u
p
n
i
1
N
I
K
T
K
T
1
N
I
088
IN2
NOP/PT/OP/
TK/TK1/KSA/
KSM/F/S6
S6
NOP
IN2 input
089
t
u
p
t
u
o
A
O
K
T
K
T
A
O
090
t
u
p
t
u
o
B
O
L
C
N
L
C
N
B
O
091
t
u
p
t
u
o
C
O
W
S
A
W
S
A
C
O
092
t
u
p
t
u
o
D
O
P
O
N
P
O
N
D
O
093
t
u
p
t
u
o
1
O
P
O
N
P
O
N
1
O
094
O2
NOP/TK/OP/
OM/ML/NCL/
NCW/ASL/
ASW/MLL/
OP1/TOE
ASW
ASW
O2 output
095
TM1
1-250
20
20
Time setting for motor run
automatically at on
096
TM2
1-250
20
20
Time setting for motor run
automatically at off
097
UTD
ON/OF
OF
OF
Motor run automatically
098
VER
---
---
---
Software version
4.1. Shortcut For Parameter Setting
:
Key for act or close multi fabric joint together.
Press and hold 2 seconds to enter [C1 01]
to set how many pieces fabric to joint.
Press lightly to select
[C1 xx ~ C5 xx]
circulation.
Value increment / decreasing.
1
Value saving, escape the display.
To act or close presser foot lifting.
Press and hold 2 seconds to enter {AFP} parameter setting.
Select { AFP~ESS } related parameter cycle by tap.
Value increment / decreasing.
2
Value saving, escape the display.
To act or close front air suction/front tape cutter.
Press and hold 2 seconds to enter {FDS} parameter setting.
Select { FDS~I1V } related parameter cycle by tap.
Value increment / decreasing.
3
Value saving, escape the display.
To act or close rear air suction/rear tape cutter.
Press and hold 2 seconds to enter {BDS} parameter setting.
Select { BDS~RDN } related parameter cycle by tap.
Value increment / decreasing.
4
Value saving, escape the display.
To act or close sensor.
Press and hold 2 seconds to enter {SMP}.
Select { SMP~STP } related parameter cycle by tap.
Value increment / decreasing.
5
Value saving, escape the display.
Display count or not available
[TKN]press and hold 2 seconds to enter TKN
Incremental value/Diminished; by manual
6
Value stored and escape , press and hold for 2 seconds to reset
5. Basic Troubleshooting
:
n
o
it
u
l
o
s
d
n
a
n
o
it
i
d
n
o
C
m
e
l
b
o
r
p
e
h
t
f
o
e
s
u
a
C
e
d
o
c
r
o
rr
E
E.4
1. When power on, higher power voltage has been
detected.
2. Connect to a wrong AC power source.
Motor and machine will be shutting down.
Please check the AC power source.
E.7
1. Bad connection to the motor connector.
2. Synchronizer (sensor) signal error.
3. Machine locked or object stuck in the motor pulley.
4. Sewing material is too thick.
Motor and machine will be shutting down.
Please check the synchronizer (sensor) and its signal.
Please check machine head to see if any objects stuck in the
motor pulley, or machine does not rotate smoothly.
E.P
Power on, speed control unit is not at neutral position.
Speed control unit return to neutral.
6. 7-Segment Display Characters Compare Table