Fixing by screw:
Mark and drill the fire frame or base, and relevant points in the opening or on the wall. Raw plugs will
be required.
Note: Fibre Rawlplugs might be preferred rather than plastic Rawlplugs as the heat from the fire might
affect their efficiency.
Whilst the opening is ready for installation of the fire, the gas supply can be routed as required and
connected to the isolation tap via the 8mm compression fitting.
Note: In no circumstance should you use soft soldered connections to or underneath the burner tray.
Temporarily fit the burner tray and ensure a suitable gas route can be achieved.
If the fire is the manual control system, you can now place the burner tray into the firebox making sure
that the fixing points are locate properly on the firebox.
Fit the two securing screws through the front plate ensuring that the plate is in correct position in the
box; secure the two screws at the back of the tray. Connect the gas supply and tighten the gas
connections.
With the slide control option please reverse the previous removal instructions taking care to a line the
linkage system as shown below.
Surplus tension cable
MUST NOT
be cut off as this
will prevent proper installation after servicing simply
coil up the surplus cable as shown and tuck the coils
out of the way.
Section 7.2: FITTING THE BURNER TRAY