13
QUARTZ-ONYX
Hardware Manual
IMPORTANT:
Minimum and maximum values are over the operating
temperature range of -30 to +75°C, typical values are at +25°C.
Table 8.
RS232 Receiver Characteristics
Receiver Parameter
Min
Typ
Max
Units
Voltage Range
-15
15
Volts
Threshold Low
0.6
1.3
Volts
Threshold High
1.7
2.4
Volts
Hysteresis
0.3
Volts
Resistance
3
5
7
kΩ
RS485 characteristics
Table 9.
RS485 Configuration Settings
Setting
Allowed Values
Baud Rate
300, 600, 1200, 2400, 9600, 19200, 38400, 57600, 115200
Data bits
5, 6, 7, 8
Parity
None, odd, even
Stop bits
1, 2
Table 10.
RS485 Driver Characteristics
Transmitter Parameter
Conditions
Min
Typ
Max
Units
Differential Output Voltage
Unloaded, load = ∞
3.47
Volts
Differential Output Voltage
Loaded, Load = 27 Ω
1.5
Volts
Change in magnitude of driver
differential output voltage for
complimentary states
Load = 27 Ω
0.2
Volts
Common Mode Output Voltage
Load = 27 Ω
3.0
Volts
Output short circuit current
±250
mA
The RS485 port may be used in either client or server mode (server mode requires
either a fixed IP address SIM or a VPN to be configured). The QUARTZ-ONYX may be
set to either RS232 (two ports) or RS485 (one port). Selection between RS232 and
RS485 is made in software on the router configuration pages.