Troubleshooting

Problem

Possible Causes

Solution

Unit does not turn on

Battery not installed 

Install 9V alkaline battery

Battery installed incorrectly

Check polarity

Battery dead

Install new 9V alkaline battery

Power switch isn’t ON

Push switch in to turn ON

Problem with internal circuitry

Return to factory for repair. 

NOTE: 

Do not attempt repairs, 

disassemble or alter unit as this will void your warranty.

No dust prints on pickup mat

There were no dust prints present

N/A

Lifting mat didn't draw down completely to 

surface

Check positioning of brass contacts between the mat 

and ground plane
Increase voltage setting

Brass contacts positioned incorrectly

Check positioning of brass contacts between the mat 

and ground plane

Lifted dust prints are very light

Lifting mat didn't draw down completely to 

surface

Check positioning of brass contacts between the mat 

and ground plane
Increase voltage setting

Brass contacts positioned incorrectly

Check positioning of brass contacts between the mat 

and ground plane

Not all dust offers high contrast

Darken room and use oblique lighting to examine

sion purposes. Secure the pickup mat (black side up) inside the transportation box 

with tape as shown to the right (Fig. 6) and seal the 

box with three evidence integrity seals. Affix the evi

-

dence identification label to the outside (Fig. 7) and 

complete the information for transportation to the lab.

References

Bodziac, William J., 

Footwear Impression Evidence,

 New York: Elsevier Science Publishing Co.: 1990, p103

Saferstein, Richard, Ph.D., 

Criminalistics, Sixth Edition,

 New Jersey: Prentis Hall: 1998, p324

Crime-Scene-Investigator, Dwayne S. Hilderbrand, CLPE: 

Footwear, The Missed Evidence,

 <

http://www.crime-scene-investigator.net/footwear.

html

> February 2009

FIGURE 7

FIGURE 6

Содержание ESP900

Страница 1: ...ke tire tracks and footprints is not the problem It s the not so obvious dust print impres sions that are difficult to locate accidentally damaged or obliterated The Electrostatic Dust Print Lifter is...

Страница 2: ...vided ESP900 Contents 1 Electrostatic Voltage Control Unit 1 Ground Plane nickel plated steel 4 x 6 10 2cm x 15 2cm 1 Ground Plane Polycarbonate Insulating Sheet 5 x 7 12 7cm x 17 8cm 1 Insulated Roll...

Страница 3: ...of LEDs RED High Voltage Ready will light when an electrical path has been established between the pickup mat and the ground plate GREEN Voltage LED s indicate the strength of the voltage output If no...

Страница 4: ...r tab with the terminals making contact 4 With the battery in position replace the compartment cover The unit is ready for use Press the ON OFF switch The green button should illumi nate NOTE Energizi...

Страница 5: ...tton The button should illuminate and the red LED below the voltage control knob will illuminate if the unit is properly position over the pickup mat and ground plate If the red LED does not come on m...

Страница 6: ...ltage and auto matically reset the control knob to the High Voltage off position 9 Lift the mat and examine the black surface for dust prints Lifting Dust Prints from Metal Surfaces The ESP900 also li...

Страница 7: ...print Lifter No 647C100 or Sirchie s GELifters CAUTION Attempts to add clear lacquer or similar materials to preserve the print on the lifting mat usually results in the destruction of lifted prints C...

Страница 8: ...ifting mat didn t draw down completely to surface Check positioning of brass contacts between the mat and ground plane Increase voltage setting Brass contacts positioned incorrectly Check positioning...

Отзывы: