XSNet C3100MC
V1
2
The Port Status LEDs
LEDs State
Indication
Steady
Power redundant system or ports function abnormally
FAULT
Off
Power redundant system and ports function normally
Steady
Power on
PWR stands for POWER
PWR1
PWR2
Off Power
off
Steady
Connection at the speed of 100Mbps
100 (Mbps)
Off
Connection at the speed of 10Mbps
Steady
LFPT function enabled
LFP
Off
LFPT function disabled
Steady
Valid network connection established
LNK stands for LINK
Flashing
Transmitting or receiving data
ACT stands for ACTIVITY
LNK/ACT
Off
Neither valid network connection established nor
transmitting/receiving data
Steady
Connection in full-duplex mode
FDX stands for FULL-DUPLEX
Flashing
Collision occurred
COL stands for COLLISION
FDX/COL
Off
Connection in half-duplex mode
Functional Description
Meets NEMA TS2 Environmental requirements: temperature, shock, and vibration for traffic control equipment.
Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial environment.
Supports 802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, full/half-duplex. Auto MDI/MDIX.
100Base-FX: Multi mode/Single mode SC type. 100Base-BX: WDM Multi mode/Single mode SC type.
One DIP switch for configuring link-fault-pass-through, fixed speed, full/half duplex, and link down alarm.
Alarms for power and port link failure by relay output. Relay contact rating with current 1.5A @ 24VDC, 0.5A @ 120VAC.
Operating voltage and Max. current consumption: 0.36A @ 12VDC, 0.18A @ 24VDC, 0.09A @ 48VDC. Power consumption: 4.32W Max.
Power Supply: Redundant DC Terminal Block power inputs.
Field Wiring Terminal: Use Copper Conductors Only, 60/75
°C
, 12-24 AWG torque value 7 lb-in.
-40
°C
to 75
°C
(-40°F to 167°F) operating temperature range. Tested for functional operation @ -40
°C
to 85
°C
(-40°F to 185°F). UL1604
Industrial Control Equipment certified Maximum Surrounding Air Temperature @ 74
°C
(165°F).
Supports Din-rail, Panel, or Rack Mounting installation.
UL1604 Class I, Division 2 Classified for use in hazardous locations (applicable to versions with terminal block power option).
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D OR non-hazardous locations only.
WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been removed or the area is known to be
non-hazardous.
WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability for Class I, Division 2.
Assembly, Startup, and Dismantling
Assembly: Place the media converter on the DIN rail from above using the slot. Push the front of the media converter toward the mounting
surface until it audibly snaps into place.
Startup: Connect the supply voltage to start up the media converter via the terminal block.
Dismantling: Pull out the lower edge and then remove the media converter from the DIN rail.