XSNet C3100MC 

 

V1 

2

The Port Status LEDs 

 

LEDs State 

Indication 

Steady 

Power redundant system or ports function abnormally 

FAULT 

Off 

Power redundant system and ports function normally 

Steady 

Power on 

PWR stands for POWER 

PWR1 

PWR2 

Off Power 

off 

Steady 

Connection at the speed of 100Mbps 

100 (Mbps)

Off 

Connection at the speed of 10Mbps 

Steady 

LFPT function enabled 

LFP 

Off 

LFPT function disabled 

Steady 

Valid network connection established 

LNK stands for LINK 

Flashing

Transmitting or receiving data 

ACT stands for ACTIVITY 

LNK/ACT 

Off 

Neither valid network connection established nor 

transmitting/receiving data 

Steady 

Connection in full-duplex mode 

FDX stands for FULL-DUPLEX 

Flashing

Collision occurred 

COL stands for COLLISION 

FDX/COL 

Off 

Connection in half-duplex mode 

 

 

Functional Description 

 

Meets NEMA TS2 Environmental requirements: temperature, shock, and vibration for traffic control equipment. 

 

Meets EN61000-6-2 & EN61000-6-3 EMC Generic Standard Immunity for industrial environment. 

 

Supports 802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, full/half-duplex. Auto MDI/MDIX. 

 

100Base-FX: Multi mode/Single mode SC type. 100Base-BX: WDM Multi mode/Single mode SC type. 

 

One DIP switch for configuring link-fault-pass-through, fixed speed, full/half duplex, and link down alarm. 

 

Alarms for power and port link failure by relay output. Relay contact rating with current 1.5A @ 24VDC, 0.5A @ 120VAC. 

 

Operating voltage and Max. current consumption: 0.36A @ 12VDC, 0.18A @ 24VDC, 0.09A @ 48VDC. Power consumption: 4.32W Max. 

 

Power Supply: Redundant DC Terminal Block power inputs. 

 

Field Wiring Terminal: Use Copper Conductors Only, 60/75

°C

, 12-24 AWG torque value 7 lb-in. 

 -40

°C

 to 75

°C

 (-40°F to 167°F) operating temperature range. Tested for functional operation @ -40

°C

 to 85

°C

 (-40°F to 185°F). UL1604 

Industrial Control Equipment certified Maximum Surrounding Air Temperature @ 74

°C

 (165°F). 

 

Supports Din-rail, Panel, or Rack Mounting installation. 

 

UL1604 Class I, Division 2 Classified for use in hazardous locations (applicable to versions with terminal block power option). 

 

This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D OR non-hazardous locations only. 

 

WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been removed or the area is known to be 

non-hazardous. 

 

WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability for Class I, Division 2. 

 

Assembly, Startup, and Dismantling 

 

Assembly: Place the media converter on the DIN rail from above using the slot. Push the front of the media converter toward the mounting 

surface until it audibly snaps into place. 

 

Startup: Connect the supply voltage to start up the media converter via the terminal block.   

 

Dismantling: Pull out the lower edge and then remove the media converter from the DIN rail.   

 

 

 