14.  Adjust the camera’s pan/tilt holder to a desired angle, as shown below. Pan adjustment 

range is nearly 360°; rotation angle range approaches to 270°. 
Tilt is adjustable between -10° ~ 90°. 

Pan adjustment 

Tilt adjustment 

Note: 

Adjust the lens carefully within the limits mentioned above, or the cables underneath 

may be harmed. 
 

15.  Return the inner cover back to the camera module. 

 

16.  Replace the back of the dome cover. 

Align the arc area on the dome cover with the back conduit entry as shown below. 

 

17.  Screw on the two Torx screws on the side of the dome cover tightly to fasten the dome 

cover. 

 

 

Содержание IFD820 Series

Страница 1: ...IFD820 Series High Definition indoor fixed dome camera with D N Installation Manual...

Страница 2: ...than that stated in this manual Although considerable care has been taken to ensure a correct and suitably comprehensive description of all relevant components the manual may nonetheless contain error...

Страница 3: ...W 7 3 2 PACKAGE CONTENTS IFD820 8 4 CABLE DEFINITION AND REQUIREMENTS 9 4 1 INTERFACE REQUIREMENTS 9 4 2 SYSTEM COMPATIBILITY 9 4 3 POWER AND ETHERNET CABLE CONNECTION 10 4 4 CONNECTORS AND RESET BUTT...

Страница 4: ......

Страница 5: ...ts Electrical wiring and low voltage electrical connections Ethernet network technologies and Internet Protocol IP Windows environments Web browsers Video audio data and contact closure transmissions...

Страница 6: ...mbered list Step by step procedures You can follow these instructions to complete a specific task Special Bold Items you must select such as menu options command buttons or items in a list Emphasis Us...

Страница 7: ...ot operate the camera beyond the specified temperature humidity and power source ratings Verify that the power source is appropriate before you plug in and operate the unit If the camera is installed...

Страница 8: ...ecycling of electrical and electronic equipment By proper waste handling of this product you ensure that it has no negative consequences for the environment and human health which could otherwise be c...

Страница 9: ...idth With ultra high resolution users can monitor critical areas with greater detail than ever before In This Chapter Product Overview 7 Package Contents IFD820 8 3 1 Product Overview Siqura IFD820 Mu...

Страница 10: ...ing or has defects do not install or operate the product Contact your supplier for assistance Siqura IFD820 package contents Siqura IFD820 camera 1 5A power adapter indoor use only Power terminal bloc...

Страница 11: ...he browsing PC must meet the system requirements described in the table below Items Minimum Requirements Personal Computer 1 Intel Pentium IV 3 GHz or higher 2 Intel Core2 Duo 2 GHz or higher 3 2 GB R...

Страница 12: ...etwork connection To have the best transmission quality cable length shall not exceed 100 meters Connect one end of the Ethernet cable to the RJ 45 connector of the Siqura IFD820 and the other end of...

Страница 13: ...tor Reset button and connectors on the printed circuit board Connector Pin No Definition Remarks Reset button Restore to factory default BNC Analog video output Alarm I O 1 Output Alarm connection 2 O...

Страница 14: ......

Страница 15: ...Camera Dimensions 13 Surface Mount 13 Recessed Ceiling Mount 18 5 1 Camera Dimensions The Siqura IFD820 dimensions are provided in millimeters in the figure below The Siqura IFD820 dimensions 5 2 Surf...

Страница 16: ...ceiling 1 Release the two captive security screws with the supplied security Torx and open the dome cover Siqura IFD820 camera Captive Security Screw 2 Press both sides of the inner cover and remove...

Страница 17: ...se of the dome camera at the chosen installation location 6 In the marked locations drill each hole slightly smaller than the supplied screw anchors and insert the anchors into these holes 7 Fasten th...

Страница 18: ...tputs Note The power cable is omitted if using PoE 12 Access the camera browser viewer for viewing images Please refer to the Siqura IFD820 s user manual for further details Users can also use the cam...

Страница 19: ...Pan adjustment Tilt adjustment Note Adjust the lens carefully within the limits mentioned above or the cables underneath may be harmed 15 Return the inner cover back to the camera module 16 Replace t...

Страница 20: ...ents T Bar mount Trim ring Ceiling sticker Required Tools Drill Philips screwdriver Security Torx provided Mount dimensions The Surface Mount dimensions are provided in millimeters in the figures belo...

Страница 21: ...module as indicated in the figure and detach it from the dome camera s housing plate 5 Attach the camera housing plate s base to the in ceiling mount s top plate aligning the camera s rear cable entr...

Страница 22: ...ount into the opening and run the Ethernet cable through the desired cable entry 8 Secure the Unit to the ceiling Note Do Not over tighten the three fixing screws If using a power tool the slip clutch...

Страница 23: ...1 for details regarding the camera connector definition 12 Access the camera browser for viewing images Please refer to the Siqura IFD820 s user manual for further details Users can also use the camer...

Страница 24: ...en 10 90 Pan adjustment Tilt adjustment Note Adjust the lens carefully within the limits mentioned above or the cables underneath may be harmed 15 Return the inner cover to the camera 16 Close the dom...

Страница 25: ...p FUNCTIONS Brightness Manual Exposure Auto Manual Sharpness Manual Contrast Manual AGC Auto White balance Auto Manual Saturation Manual Hue Manual Rotation Flip mirror 90 and 180 rotate Backlight com...

Страница 26: ...am 2 H 264 D1 30fps MJPEG D1 30fps H 264 1080p15 MJPEG 1080p15 H 264 720p30 H 264 720p30 MJPEG 720p30 None AUDIO Compression G 711 8kHz A LAW Law 64 kbit s G 726 8kHz 40 kbit s STORAGE Storage MicroSD...

Страница 27: ...Siqura IFD820 ENVIRONMENT Operating Temperature 12VDC 24VAC 10 C to 50 C 14 F to 122 F Relative Humidity 10 90 as long as there is no condensation Note Weight and dimensions are approximate All speci...

Страница 28: ......

Отзывы: