The cleaner can only be connected to the water 

mains if the water mains is separated by a back-

flow preventer. Make sure that the hose is at least Ø 

13mm-1/2 inch and that it is reinforced.

 WARNING: Water that has flown through 

backflow preventers is considered to be 

nonpotable.

IMPORTANT: Only clean or filtered water should 

be used for intake. The delivery of the water 

intake tap should be equal to the double of the 

maximum pump range. 

-    Minimum delivery rate: 15 l/ min.

-    Maximum intake water temperature: 40°C

-    Max inlet water pressure: 1Mpa

Place the cleaner as close to the water supply system 

as possible.

Water supply from an open container

-  Unscrew the coupling part for the water inlet.

-  Screw the suction hose with filter (not included) 

onto the water connection of the unit.

-  Hang the filter in the container.

-  Vent the unit before operation.

- Unscrew the high-pressure line at the high-

pressure outlet of the unit.

-  Switch on the unit and let it run until water free of 

bubbles emerges at the high-pressure outlet.

-  Switch off the unit and screw on the high-pressure 

hose again. 

Failure to comply with the above conditions causes 

serious mechanical damage to the pump and the 

loss of warranty cover.

>  ELECTRICITY SUPPLY

- The appliance’s electrical connection must 

comply with the IEC 60364-1 standard.

 IMPORTANT: Before connecting the 

appliance, make sure that the nameplate data are 

the same as those of the electrical mains and that 

the socket is protected by a differential security 

breaker with tripping sensitivity below 0.03 A - 30 

ms.

-  If the appliance’s plug is not compatible with the 

socket, have the socket replaced with another of 

suitable type by professionally qualified staff.

-  Never use the appliance in ambient temperatures 

below 0° C if it is equipped with a PVC (H VV-F) 

cable.

 XY  WARNING:  Inadequate extension cords can 

be dangerous.

 XJ  WARNING: If an extension cord is used, 

the plug and socket must be of watertight 

construction. 

   Information for supply may also be obtained 

from the plug manufacturer.

<16 A

<25 A

<20 m 

ø 1,5 mm

2  

- 14 AWG ø 2,5 mm

 - 12 AWG

20 m - 50 m ø 2,5 mm

 - 12 AWG ø 4,0 mm

 - 10 AWG

>  PLUG

HOW TO CONNECT THE CORD TO A U.K. PLUG: 

IMPORTANT The wires in the mains lead are 

coloured in accordance with the following code:

 

Blue 

  Neutral

 

Brown 

  Live

 Yellow/Green   

Earth

Please read the instructions given below before con-

necting the cord to a plug. If in doubt please consult 

a qualified electrician. As the colours of the wires in 

the mains lead of this appliance may not correspond 

with the coloured markings identifying the termi-

nals in your plug, proceed as follows:

The wires that is coloured Brown must be connected 

to the terminal which is marked with the letter L or 

coloured Red. The wire that is coloured Blue must be 

connected to the terminal which is marked with the 

letter N or coloured Black.

Safety points for rewireable or moulded plug:

The mains lead of this appliance may be already 

fitted with a BS1363 13A plug.

-  If your socket outlet is not suitable for the plug, 

then the plug must be removed (cut off if it is a 

moulded on plug), the flexible cord insulation 

should be stripped back as appropriate and a 

suitable 3 pin plug fitted.

 

WARNING: Dispose of 

a plug that has been 

cut from the power 

supply cord, as such 

a plug is hazardous 

if inserted in a live 

13A socket outlet 

elsewhere in the 

house. 

 

Should the fuse 

need to be replaced 

an ASTA marked fuse, 

approved to BS1362, of the same rating must be 

used. 

 -  Always replace the fuse cover after fitting a fuse. 

Содержание CW2300

Страница 1: ...Technical data plate HIGH PRESSURE CLEANER WARNING read the instructions carefully before use SIP CW2300...

Страница 2: ...le 2 ON OFF switch 3 Detergent tank 4 Water outlet 5 High pressure hose 6 Gun 7 Lance 8 Turbo Lance 9 Electric cable 10 Water inlet filter Quick hose fitting DESCRIPTION OFTHE MACHINE 2 1 10 6 5 8 7 3...

Страница 3: ...6 5 ck click click OPTIONAL X2 ASSEMBLY INSTRUCTIONS Depending on the model there are differences in the scopes of delivery 3...

Страница 4: ...A B C D Optional IN OUT 1 4 2 3 ON I 5 2 5 40 C Optional 1 2 inch 13 mm 15 30 45 60 1 IN 1 min 4...

Страница 5: ...E G F 1 2 3 5...

Страница 6: ...D 6 spread pattern pencil jet H turbo lance Low pressure foam mode 2 1 Optional I K 2 3 CLICK 4C 3C Optional Low pressure and foam mode...

Страница 7: ...Use the hydrocleaner only if the hose is completely uncoiled and extended 7 1 2 3 L Optional N OFF 1 2 3 4 M 4 1 2 3 L Optional N OFF 1 2 3 4 M 4 OPTIONAL HIGH PRESSURE HOSE...

Страница 8: ...e cleaned from a minimum distance of 30 cm otherwise the vehicle tyre tyre valve could be damaged by the high pressure jet The first indication of this is a discoloration of the tyre Damaged vehicle t...

Страница 9: ...k of explosion Do not spray flammable liquids 22WARNING To ensure machine safety use only original spare parts from the manufacturer or ap proved by the manufacturer 23WARNING Do not direct the jet ag...

Страница 10: ...ble type by professionally qualified staff Never use the appliance in ambient temperatures below 0 C if it is equipped with a PVC H VV F cable XY WARNING Inadequate extension cords can be dangerous XJ...

Страница 11: ...ease the lever on the trigger gun NOTE Release the lever of the trigger gun the device will switch off again High pressure remains in the system See fig E Lock the lever on the trigger gun Operation S...

Страница 12: ...t pipes to the pump for leaks or blockage Strong pressure fluctuations Clean the high pressure nozzle Remove dirt from the nozzle hole with a needle and then rinse out with water from the front Pump l...

Страница 13: ...falling within the usual maintenance such as Gaskets diaphragms sealing rings oil and so on The Manufacturer shall not be held responsible for accidents to the operator or third parties while the equi...

Страница 14: ...14...

Страница 15: ...r s Authorised Representative Declare that the SIP CW2000 Pressure Washer SIP Part No 08970 SIP CW2300 Pressure Washer SIP Part No 08972 Conforms to the requirements of the following Directive s as in...

Страница 16: ...cod 7 100 2265 00 12 2018 16...

Отзывы: